Item
Condition
Measurement
Adjustment
Specifications/
Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
PC test mode
Panel tuning mode
ADJUSTMENT
NX-800
55
8. QT Deviation
adjust *4
[Narrow]
[Wide]
9. DQT
Deviation
adjust *4
[Narrow]
[Wide]
10.LTR
Deviation
adjust *4
[Narrow]
[Wide]
11.DTMF
Deviation
adjust *4
[Narrow]
[Wide]
Deviation
meter
Oscilloscope
ANT
Write the value as
followings.
513 (Reference
value)
Write the value as
followings.
430 (Reference
value)
Write the value as
followings.
465 (Reference
value)
Write the value as
followings.
650 (Reference
value)
0.30~0.40kHz
0.70~0.80kHz
0.30~0.40kHz
0.70~0.80kHz
0.65~0.85kHz
0.90~1.10kHz
1.40~1.60kHz
2.90~3.10kHz
[Panel
tuning
mode]
[
],[
]
[PC test
mode]
[ ],[ ]
1) Adj item:[An QT]
Adjust:[****]
Deviation meter
LPF : 3kHz
HPF : OFF
PTT : ON
Press [
] key to store
the adjustment value.
1) Adj item:[Aw QT]
Adjust:[****]
PTT : ON
Press [
] key to store
the adjustment value.
1) Adj item:[An DQT]
Adjust:[****]
Deviation meter
LPF : 3kHz
HPF : OFF
PTT : ON
Press [
] key to store
the adjustment value.
1) Adj item:[Aw DQT]
Adjust:[****]
PTT : ON
Press [
] key to store
the adjustment value.
1) Adj item:[An LTR]
Adjust:[****]
Deviation meter
LPF : 3kHz
HPF : OFF
PTT : ON
Press [
] key to store
the adjustment value.
1) Adj item:[Aw LTR]
Adjust:[****]
PTT : ON
Press [
] key to store
the adjustment value.
1) Adj item:[An DTMF]
Adjust:[****]
Deviation meter
LPF : 15kHz
HPF : OFF
PTT : ON
Press [
] key to store
the adjustment value.
1) Adj item:[Aw DTMF]
Adjust:[****]
PTT : ON
Press [
] key to store
the adjustment value.
1) Adj item:[QT
Deviation (Narrow)]
Deviation meter
LPF : 3kHz
HPF : OFF
PTT : Press [Transmit]
button.
Press [Apply] button to
store the adjustment value.
1) Adj item:[QT
Deviation (Wide)]
PTT : Press [Transmit]
button.
Press [Apply] button to
store the adjustment value.
1) Adj item:[DQT
Deviation (Narrow)]
Deviation meter
LPF : 3kHz
HPF : OFF
PTT : Press [Transmit]
button.
Press [Apply] button to
store the adjustment value.
1) Adj item:[DQT
Deviation (Wide)]
PTT : Press [Transmit]
button.
Press [Apply] button to
store the adjustment value.
1) Adj item:[LTR
Deviation (Narrow)]
Deviation meter
LPF : 3kHz
HPF : OFF
PTT : Press [Transmit]
button.
Press [Apply] button to
store the adjustment value.
1) Adj item:[LTR
Deviation (Wide)]
PTT : Press [Transmit]
button.
Press [Apply] button to
store the adjustment value.
1) Adj item:[DTMF
Deviation (Narrow)]
Deviation meter
LPF : 15kHz
HPF : OFF
PTT : Press [Transmit]
button.
Press [Apply] button to
store the adjustment value.
1) Adj item:[DTMF
Deviation (Wide)]
PTT : Press [Transmit]
button.
Press [Apply] button to
store the adjustment value.
*4: Refer to the “Mode, Signaling, Necessary adjustment and order” table on page 57.