ADJUSTMENT
NX-800
44
Controls
Panel Test Mode
■
Test mode operation features
This transceiver has a test mode.
To enter test mode,
press and hold the [
] key while turning the transceiver
power ON. Before the transceiver enters test mode, the
frequency version information appears on the LCD mo-
mentarily.
Test mode can be inhibited by programming. To
exit test mode, turn the transceiver power OFF. The follow-
ing functions are available in test mode.
■
Key operation
Key
“FNC” not appears on the sub LCD display
Function
Display
[
] / [
]
Test CH up/down
Channel No.
[
] / [
]
Volume up/down
-
[
]
Push: Squelch level up
Squelch level
Hold: Squelch off
Squelch off: icon appears
Wide : “w”
[ ]
Wide/Narrow/Very narrow
Narrow : “n”
Very narrow : “v”
[ ]
Shift to panel tuning mode
-
[
]
Function on
“
FNC
” appears on the
sub LCD display
[
]
MSK 1200bps and 2400bps
2400bps :
icon appears
[
]
Test signaling CH up
Signaling No.
Key
“FNC” not appears
Function
Display
Microphone key
[PTT]
Transmit
-
[0] to [9]
Use as the DTMF keypad.
and
If a key is pressed during
[A] to [D],
transmission, the DTMF
-
[#], [
*
]
corresponding to the key
that was presses is sent.
Key
“FNC” appears on the sub LCD display
Function
Display
[
]
-
-
[
]
Analog/NXDN
Analog: “A”
NXDN: “N”
[
] / [
]
Function off
-
[
]
-
-
[ ]
LCD all lights
LCD all point appears
[ ]
High power/Low power
Low:
icon appears
[
]
Function off
-
[
]
Compander on/off
On:
icon appears
[
]
Beat shift on/off
On: icon appears
Microphone key
[PTT]
Transmit
[0] to [9]
and
Function off
-
[A] to [D],
[#], [
*
]
• LED indicator
Red LED
Lights during transmission.
Green LED
Lights when there is carrier.
• Sub LCD indicator
“FNC”
Appears at function on.
• LCD display in panel test mode
KMC-36
Modular
MIC jack
Keypad
[HOOK]
Channel Up/Down key
[PTT]
Power switch
Volume Up/Down key
Programmable function keys
An SQ5 1- 1
Channel No.
An : Analog narrow mode
Aw : Analog wide mode
Nn : NXDN narrow mode
Nv : NXDN very narrow mode
Sub LCD
display
+25
Signaling No.
Main LCD display
Squelch level
(Analog mode only)
Temperature