Item
Condition
Measurement
Adjustment
Specifications/
Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
PC test mode
Panel tuning mode
ADJUSTMENT
NX-800
60
6. Low RSSI at
-118dBm
adjust *7
[Analog
Narrow]
[Analog
Wide]
[NXDN Very
Narrow]
1) Adj item:[An LRSSI]
Adjust:[***]
2) Adj item:
[AnL LRSSI]
→
[AnL’ LRSSI]
→
[AnC LRSSI]
→
[AnH’ LRSSI]
→
[AnH LRSSI]
SSG output :
-118dBm (0.28
µ
V)
(MOD: 1kHz,
Dev:
±
1.5kHz)
1) Adj item:[Aw R
LRSSI]
Adjust:[***]
2) Adj item:
[AwL LRSSI]
→
[AwL’ LRSSI]
→
[AwC LRSSI]
→
[AwH’ LRSSI]
→
[AwH LRSSI]
SSG output :
-118dBm (0.28
µ
V)
(MOD: 1kHz,
Dev:
±
3kHz)
1) Adj item:[Nv LRSSI]
Adjust:[***]
2) Adj item:
[NvL LRSSI]
→
[NvL’ LRSSI]
→
[NvC LRSSI]
→
[NvH’ LRSSI]
→
[NvH LRSSI]
SSG output :
-118dBm (0.28
µ
V)
(MOD: 1kHz,
Dev:
±
1.5kHz)
1) Adj item:[Low RSSI
(Narrow)]
2) Adj item:[Low]
[Low’]
[Center]
[High’]
[High]
SSG output :
-118dBm (0.28
µ
V)
(MOD: 1kHz,
Dev:
±
1.5kHz)
1) Adj item:[Low RSSI
(Wide)]
2) Adj item:[Low]
[Low’]
[Center]
[High’]
[High]
SSG output :
-118dBm (0.28
µ
V)
(MOD: 1kHz,
Dev:
±
3kHz)
1) Adj item:[Low RSSI
(Very Narrow)]
2) Adj item:[Low]
[Low’]
[Center]
[High’]
[High]
SSG output :
-118dBm (0.28
µ
V)
(MOD: 1kHz,
Dev:
±
1.5kHz)
SSG
ANT
Ext.SP
connector
[Panel test mode]
After input signal
from SSG, press
[
] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the
adjustment value.
Adjust with the
analog signal.
*7: Because “RSSI at -118dBm adjust” of NXDN Narrow is adjusted by adjusting “RSSI at -118dBm adjust [Analog Narrow]”, it is not necessary to
adjust “RSSI at -118dBm adjust” of NXDN Narrow.