NOV/2005
Section B – Page #13
STEP ILLUSTRATION
STEP 10
Remove the charge kit adapter
(3) and o-ring (4). Reinstall the
Accumulator Plug and O-ring.
Step 11
Close the valve on the nitrogen
tank and bleed off nitrogen
pressure by slowly opening the
shut-off valve (12). Once the
pressure gauges on the tank read
0 psi, close shut-off valve.
The accumulator is now charged.
Store the charging kit for later
use.