The KENT GEM Non-Electric Mineral RO™ Water Purifier is a product of advanced technology,
which ensures safe and clean drinking water. The purifier is easy and convenient to install.
Recommended Site Preparations:
• Raw water supply with ½ inch nipple not more than 3m away
• Drain for rejected water not more than 3m away
• Space as per dimensions of the purifier
Specific Instructions:
• For optimum performance, the minimum and maximum inlet water pressure should be in the
2
2
range of 2.81 kg/cm or 40 psi or 6.12 kg/cm or 87 psi 2.81kg/cm -6.12kg/ cm (40 psi-87 psi)
• It is preferable to install the purifier near a sink, so that inlet and reject water lines are easily available.
2
2
Automatic Operation
Installation Instructions
• The purifier automatically shuts off when the
• The purifier does not allow any water
storage tank becomes full and faucet is
rejection when tank is full and faucet is in
closed.
closed condition due to automatic shut –off
valve.
• The purifier does not start when inlet water
2
supply pressure is below 2.81 kg/cm or 40 psi.
5
6
TDS Adjustment
The unique TDS Controller enables customers to retain the contents of natural minerals in
purified water, as per their requirement.
• Turning the screw of the valve anti-
• Turning the screw of the valve clockwise,
clockwise, results in an increased mineral
results in a decreased mineral content.
content
Starting Up the Purifier
Recommended Uses of Rejected Water
• Connect to the main water supply [as
order to remove residual dust particles
shown in the figure] and turn it on.
present in the pipes or storage tank.
• Wait till the storage tank fully fills up. **
• Turn on the water supply.
• Turn off the water supply.
• The purifier is ready to use.
• Open the tap or faucet and drain the tank in
Rejected water has high concentration of salts and usually goes down the drain, but if required, can
be used for gardening purposes. Its high concentration of salts and minerals accelerate plant
growth. Rejected water can also be used for cleaning purposes, i.e. utensils cleaning, mopping,
etc.
.Pressure Testing & Purging
1. Check all tubes to ensure that there are no obstructions.
2. Turn on the faucet.
3. Slowly turn on the main water supply and check for leaks.
4. It should
take more than 5 minutes to purge air from the system. Once water starts flowing from
the faucet, keep it on for 20 minutes.
5. After 20 minutes, turn faucet off.
not
Installation Procedure
4.
Connect one end of blue pipe to elbow fitting connector labeled as
REJECT WATER and lead the other end to drain.
1.
Fasten the SS ball valve to the ¼ inch port of the 3-way connector.
2.
Attach threaded end of 3-way connector to raw water supply and plug-off the
other end or connect to a tap.
3.
Now connect one end of white pipe to SS ball valve and other end to
elbow fitting connector labeled as Raw Water, on the back side of purifier.
Use white pipe for raw water supply
5.
6.
Turn on the lever given on SS ball valve to initiate the water flow to the purifier.
Allow the filters to pre-soak in water for 2-3 minutes.
7.
Installation is complete.
Note:
• In case, you choose to place water purifier under the counter, install the faucet on the kitchen sink
or slab, connect one end of the white pipe to the faucet and the other end to the fitting connector
labeled as ‘Faucet’ on the back side of the purifier
• If the water purifier is placed as ‘Table Top’, never remove the dead plug from the connector
labeled as faucet
Use blue pipe for reject water