background image

-20010

SP Inline Sediment Filter 8”

-20009

SP Inline Carbon Block Filter 8”

-20002

SP RO Membrane Welded 8” Housing

-20004

SP UF Membrane Welded 8” Housing

-20018

SP FRT 550

Note: 

Filters and membrane are consumables. Their replacement time depends upon the quality of raw 

water and water consumption. They are not covered under the warranty. However, if a filter chokes 
within  six  months  and  a  membrane  within  a  year,  it  will  be  cleaned/repaired/replaced  free  of  cost. 
Changing the filters and system inspection is available on call. The treatment capacity of RO membrane 
will reduce with time due to clogging of pores of membranes.

“This reverse osmosis system contains a replaceable component critical to the efficiency of the system. 
Replacement  of  the  reverse  osmosis  component  should  be  with  one  of  identical  specifications  as 
defined by the manufacturer, to ensure the same efficiency and contaminant reduction performance.”

Technical  Specifications

7

8

Replacement  of  spare  parts  are  as  under:-

MODEL

:

KENT  GEM  Mineral  RO™  Non-Electric

Product  Code

:

11045

Applications

:

Suitable  for  Purification  of  Brackish  / 
Tap Water  /  Municipal Water  Supply

Operating  pH  levels

:

2-11

Body  Material

:

ABS  Food  Grade  Plastic

Mounting

:

Counter Top/Under  the  counter

Dimensions(mm)

:

L  440  x W  250  x  H  400

2

Inlet Water  Pressure/Temp  (Min)

:

2.81  kg  /  cm   or  40  psi  /  10°C  or  50°  F

2

Inlet Water  Pressure/temp  (Max)

:

6.12  kg  /  cm   or  87  psi  /  40°C  or  104°  F

Filter  Cartridge

:

Sediment  and  activated  Carbon  Filter

UF  Filter

:

Ultra  Filtration  Membrane

Weight

:

9.300  kg

Storage  Capacity

:

5  L

Maximum  Duty  Cycle

:

75  L/day

Membrane Type

:

Thin  Film  Composite  RO

* Purification capacity tested for raw water having TDS level of 750 ppm at room temperature.

Maintenance

To ensure that the purifier operates at its optimum level, a routine maintenance must be performed. 
The frequency of the maintenance will greatly depend upon the raw water quality and consumption 
of treated water.

• Storage  tank  must  be  drained  once  in  2 

• Replace the RO membrane once every year.

weeks. To do so, switch off the water supply 

• Replace the UF membrane once every year.

and open the tap or faucet and drain the tank.  

• If you are not going to use the purifier for a 

• Replace  sediment  and  activated  carbon 

long time (in case you are on a holiday, tour 

after every 12 months. It is recommended to 

or out of home), make sure that you turn off 

change  the  FRT  when  the  filters  are 

the raw water supply and drain the storage 

replaced.

tank.

Note: The reverse  osmosis  system  contains  a replaceable treatment  component  critical  for the 
effective reduction of total dissolved solids and that produced water shall be tested periodically to 
verify that the system is performing properly.