3

OPERATION

OPERATION

W

arranty

Saf

ety

Cleaning

Operation

Installation

Ser

vice P

a

rt

s

Always turn ON your hood before you begin cooking in order 

to establish an air 

fl

 ow in the kitchen. Let the blower run for a 

few minutes to clear the air after you turn off the range. This 

will help keep the whole kitchen cleaner and brighter.

1. Blower Delay switch  

     4. Filter maintenance indicator

2. ON/OFF Blower speed switches  

5. Nightlight switch                

3. Halogen lights switch

ON/OFF Blower speed switches

Press the switch corresponding to the desired blower speed. 

The light over the switch indicates the selected speed (from 

1

 

for low speed to 

4

 for high speed). To turn off the blower, press 

once more on the corresponding blower speed switch.

HEAT SENTRY™

Your hood is equipped with a HEAT SENTRY thermostat. This 

thermostat is a device that will turn on or speed up the blower if 

it senses excessive heat above the cooking surface. The light 

indicator over speed 

3

 switch will quickly 

fl

 ash.

1) If blower is OFF - it turns blower ON to speed 

3

.

2) If blower is ON at a lower (or higher) speed setting - it turns 

  blower to speed 

3

.

When the temperature level drops to normal, the blower will 

return to its original setting and the light indicator over speed 

3

 

switch will stop 

fl

 ashing.

Halogen lights switch

This switch provides 3 different lighting levels, according to 

your needs. The lighting intensity changes by increments of 1 

(i.e.: press once for low intensity, once again to get more, up 

to three times). From the higher intensity, press once again to 

shut off the lights.
Uses 120 Volts, 50 W, MR 16 with GU10 base or PAR 16 with 

GU10 base, shielded halogen bulbs (included).

WARNING: The HEAT SENTRY thermostat can 
start the blower even if the hood is turned OFF. 
When this occurs, press the speed 3 switch 
until its light indicator stops fl ashing if you 
must stop the blower.

Delay OFF switch

When a speed is selected, press the Delay OFF switch to 

activate the delay function. The corresponding speed indicator 

LED will start 

fl

 ashing to indicate this function is activated. 

The fan will continue to operate for 5 minutes and will stop 

automatically. To cancel the delay function, press the Delay 

OFF switch once again; the blower will then work in normal 

mode.
NOTE:  The blower speed can be increased or decreased during 

Delay mode without starting another 5-minute cycle.

1

5

HC0027

2

3

4

WARNING: In order to prevent the risk of 
personal injury, do not install a lamp identifi ed 
for use only in enclosed fi xtures.

Grease fi lters

The grease 

fi

 lters should be cleaned fr

equently. Use a warm 

detergent solution. Grease 

fi

 lters are dishwasher safe.

Wash more often if your cooking style generates greater grease 

- like frying foods or wok cooking.
Remove filters by pulling latch tabs and rotating filters 

downward.

Hood Cleaning

Stainless steel cleaning: How to maintain its “BRIGHT LOOK”

Do:

-  Regularly wash surfaces with clean cloth or rag soaked with 

warm water and mild soap or liquid dish detergent.

-  Always clean in the direction of original polish lines.
-  Always rinse well with clear water (2 or 3 times) after cleaning. 

Wipe dry completely.

-  You may also use a specialized household stainless steel 

cleaner.

Don’t:

-  Do not use any steel or stainless steel wool or any other 

scrapers to remove stubborn dirt.

-  Do not use any harsh or abrasive cleaners.
-  Do not allow dirt to accumulate.
-  Do not let plaster dust or any other construction residues 

reach the hood. During construction/renovation, cover the 

hood to make sure no dust sticks to stainless steel surface.

Avoid: when choosing a detergent

-  Any cleaners that contains 

bleach

 will attack stainless 

steel.

-  Any products containing: 

chloride

fl uoride

iodide

bromide

 

will deteriorate surfaces rapidly.

-  Any combustible products used for cleaning such as 

acetone

alcohol

ether

benzol

, etc., are highly explosive

and should not be used close to a range.

Filter maintenance indicator

After 24 hours of operation, the 

fi

 lter maintenance light indicator 

will start blinking. This indicates the 

fi

 lters need to be cleaned 

in order to maintain ef

fi

 cient operation of the unit. The indicator 

light will blink until the function is reset by pressing the nightlight 

switch for 3 seconds.

CLEANING

Nigthlight switch

Press this switch once to turn on the nightlight. Press this switch 

once more to shut off the nightlight.

Summary of Contents for 31130

Page 1: ...Models 31130 30 wide Stainless 31133 36 wide Stainless Range Hood Use Care Guide Installation Manual ENGLISH 09030 rev A SEARS CANADA INC Toronto Ontario M5B 2B8 www sears ca HB0108 ...

Page 2: ... explosive materials and vapors 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 4 Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated The motor will restart when it cools down If the motor continues to shut off and restart have the hood serviced 5 For best capture o...

Page 3: ... will continue to operate for 5 minutes and will stop automatically To cancel the delay function press the Delay OFF switch once again the blower will then work in normal mode NOTE The blower speed can be increased or decreased during Delay mode without starting another 5 minute cycle 1 5 HC0027 2 3 4 WARNING In order to prevent the risk of personal injury do not install a lamp identified for use ...

Page 4: ...INCLUDED WITH HOOD HR0051 120 V 50 W PAR16 with GU10 base shielded halogen lamp 2 per hood Sears Part No V05921 Ducting Accessories See Range Hood System on page 5 for Ducting Accessory Model Nos Optional flue extension for 10 ft ceilings model no 31131 HR0012 HR0010 HR0011 3 x 10 adapter damper for horizontal discharge HR0041 8 round adapter damper for vertical discharge in a separate box HR0042 ...

Page 5: ...d Elbow Ductwork Warranty Safety Cleaning Operation Service Parts Installation Broan Model 639 3 x 10 Standard Wall Cap Upper Decorative Flue Lower Decorative Flue Single Blower supplied with hood Adapter damper 8 round supplied with hood For vertical discharge Broan Model 401 Standard 3 x 10 Duct Adapter damper 3 x 10 supplied with hood For horizontal discharge Adapter dampers ...

Page 6: ...ntly when attached to long runs of duct As a point of reference this hood will function at approximately 80 of its rated air performance when 300 equivalent feet of 8 round ductwork is attached Use this chart to calculate the equivalent duct length of your system Note that 8 round is the minimum recommended duct size HR0046 8 in Round Elbow Equivalent length 10 ft Broan Model 639 3 x 10 Wall Cap E...

Page 7: ...izontal ductwork Refer to page 8 for more details SELECT INSTALLATION TYPE Warranty Safety Cleaning Operation Installation Service Parts 8 ROUND DUCT ROOF CAP 3 X 10 DUCT WALL CAP HOOD DECORATIVE FLUE HH0134A REFER TO CHART FOR DISTANCE ABOVE COOKING SURFACE Refer to illustrations below to locate duct opening according to discharge type chosen grey parts to be installed later CEILING HEIGHT MINIMU...

Page 8: ...k of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WIRING INSTALLATION Position the outlet within the space covered by the decorative flue Place the outlet at a maximum distance of 24 from where the cord exits fro...

Page 9: ...ontal discharge may be positioned on higher OR on lower back of the hood From outside the unit remove the knockout for the chosen discharge opening see illustrations beside HR0038 1 2 OR OR PREPARE THE HOOD Warranty Safety Cleaning Operation Installation Service Parts 1 Lay the hood on its back on a table Remove grease filters by lifting the metal latch tab 1 pushing down on the filter 2 and tilti...

Page 10: ... to the inner back of the hood once the hood is mounted on the wall 3 Uplug the blower HE0085 6 Secure the adapter damper to the back of the hood using 2 no 8 x 3 8 screws included Seal the adapter damper to the hood using metal foil duct tape NOTE The wall ducting must be properly prepared to receive the adapter Before performing the installation make sure the adapter fits easily in the duct NOTE...

Page 11: ... x 3 4 screws Ensure that the bracket is tight against the wall HD0377 C L CEILING SCREW LOCATIONS MOUNTING BRACKET FLUSH WITH CEILING WARNING BE CAREFUL when installing the decorative flue and hood they may have sharp edges CAUTION DO NOT REMOVE the protective plastic film covering the decorative flue upper lower 3 Align the hood and center it above the hood mounting bracket Gently lower the hood...

Page 12: ... lower flue as they are not needed HO0144 Both lower and upper flues are included with the hood but for a 10 foot ceiling discard the provided upper flue and use the optional extension flue part no 31131 purchase separately NOTE 2 Carefully slide in place decorative flue base notches end first between the shaded part and the exterior wall of the top of the hood HO0143 LOWER FLUE REAR NOTCH LOWER F...

Page 13: ... flue FINALIZE THE INSTALLATION This range hood must use 2 shielded halogen lamps 120 V 50 W PAR16 with GU10 base included Refer to page 4 for ordering information WARNING In order to prevent the risk of personal injury do not install a lamp identified for use only in enclosed fixtures WARNING In order to prevent the risk of personal injury the halogen lamps must cool down before removing them 1 T...

Page 14: ...GU10 2 2 10 05921 SHIELDED HALOGEN LAMP 120V 50W GU10 2 2 11 09022 TRANSFORMER 1 1 12 08582 INTERNAL BLOWER INCLUDING CAPACITOR 1 1 13 08783 CAPACITOR 1 1 14 18523 MICROMESH FILTERS 13 83 X 13 83 SET OF 2 1 1 15 09035 KENMORE ELITE LOGO 1 1 16 09014 HOOD MOUNTING BRACKET 1 1 17 08543 8 ROUND A DAPTER DAMPER 1 1 18 13296 3 X 10 ADAPTER DAMPER 1 1 09030 KENMORE ELITE INSTALLATION GUIDE 1 1 09027 PAR...

Reviews: