INSTALLATION INFORMATION: 

 

Before installing, consult Use & Care/installation instructions 
packed with product for  current dimensional data.

OPTIONAL ACCESSORIES

 

UX12DC9SLSS/BLTS – 12(ft.) Ceiling Duct Cover Kit  
Max ceiling height installation with kit – 12'-0" (36" hood spacing)
UX14DC9SLSS/BLTS – 14(ft.) Ceiling Duct Cover Kit 
Max ceiling height installation with kit – 14'-0"
UXCF91 – Charcoal Filter (needed if used in recirculation mode)
UXRC1 – Remote Control (Wireless)

AMP RATING

120V

TBD

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES) 

30" models require a 30"-wide opening

*The supplied duct cover fits 7'-7" to 9'-6" ceiling heights

(10' ceiling height with optional high ceiling kit UX10DC83SS)

 

The vent hood must be installed 24" min. above the cooking surface. For optimal performance, installing the 

hood more than 36" above the cooking surface is not recommended. The hood installation height above the

cooking surface depends upon ceiling height. The telescopic duct cover conceals the ductwork running from

the top of the hood to the ceiling.

NOTE: Installation height should be measured from the cooking surface to the lowest part

of the hood. This hood may be installed onto a wall and vented to the outdoors, or it can be installed

for recirculating operation. Parts for recirculating operation are supplied with the hood.

12-1/4"

13-13/16"

20"

29-7/8"

24" Min

36" Max

 27-1/2"

to 39-1/2"

2-3/4"

36" models require a 36"-wide opening

*The supplied duct cover fits 7'-7" to 10'-6" ceiling heights

(12' ceiling height with optional high ceiling kit UX12DC93SS/UX12DC93TS)

(14' ceiling height with optional high ceiling kit UX14DC93SS/UX14DC93TS)

 

The vent hood must be installed 24" min. above the cooking surface. For optimal performance, installing the 

hood more than 36" above the cooking surface is not recommended. The hood installation height above the

cooking surface depends upon ceiling height. The telescopic duct cover conceals the ductwork running from

the top of the hood to the ceiling.

NOTE: Installation height should be measured from the cooking surface to the lowest part

of the hood. This hood may be installed onto a wall and vented to the outdoors, or it can be installed

for recirculating operation. Parts for recirculating operation are supplied with the hood.

20-1/8"

12-1/4"

13-13/16"

35-7/8"

 27-1/2"

to 51"

2-3/4"

24" Min

36" Max

36" models require a 36"-wide opening

*The supplied duct cover fits 7'-7" to 10'-6" ceiling heights

(12' ceiling height with optional high ceiling kit UX12DC93SS/UX12DC93TS)

(14' ceiling height with optional high ceiling kit UX14DC93SS/UX14DC93TS)

 

The vent hood must be installed 24" min. above the cooking surface. For optimal performance, installing the 

hood more than 36" above the cooking surface is not recommended. The hood installation height above the

cooking surface depends upon ceiling height. The telescopic duct cover conceals the ductwork running from

the top of the hood to the ceiling.

NOTE: Installation height should be measured from the cooking surface to the lowest part

of the hood. This hood may be installed onto a wall and vented to the outdoors, or it can be installed

for recirculating operation. Parts for recirculating operation are supplied with the hood.

20-1/8"

12-1/4"

13-13/16"

35-7/8"

 27-1/2"

to 51"

2-3/4"

24" Min

36" Max

36"models require a 36"-wide opening 

*The supplied duct cover fits 7'-7" to 10'-6" ceiling heights 

(12' ceiling height with optional high celling kit UX12DC9SLSS/UX12DC9BLTS) 

(14' ceiling height with optional high celling kit UX14DC9SLSS/UX14DC9BLTS)