INSTALL THE  HOOD

1.  Construct wood wall framing that is 

fl

 ush with surface of wall 

studs.

  Wood wall framing must be at least 1/2” thick and 3” high. 

Ensure to assemble wood wall framing to wall studs for a 

solid installation.

  Ensure the height of the framing will allow the mounting 

bracket to be secured to the framing within the dimensions 

shown (see illustration beside).

  After wall surface is 

fi

 nished, carefully center and level the 

hood mounting bracket over installation location. Secure it 

to wall framing using 3 no. 8 x 1½” screws.

  Using a level, draw a vertical line up to the ceiling starting 

from the mounting bracket center.

WARNING: When cutting or drilling into wall, 
do not damage electrical wiring and other 
hidden utilities.

HD0374A

36¾” = 

BOTTOM

 

OF

 

HOOD

 24” 

ABOVE

 

COOKTOP

42¾” = 

BOTTOM

 

OF

 

HOOD

 30” 

ABOVE

 

COOKTOP

W

arranty

Saf

ety

Cleaning

Operation

Installation

Ser

vice P

a

rt

s

2.  Center the upper 

fl

 ue mounting bracket with the center line 

previously drawn and place it 

fl

 ush with the ceiling.

  Use the upper 

fl

 ue mounting bracket as a template to mark 

the position of its screws. 

  Drill the 3 screw holes using a 3/16” drill bit.

  Insert the included drywall anchors into the drilled holes 

(1 per hole).

  Secure the upper 

fl

 ue bracket to the wall using 3 no. 8 x 3/4” 

screws.

  Ensure that the bracket is tight against the wall.

HD0377

C

L

C

EILING

S

CREW

 

LOCATIONS

M

OUNTING

 

BRACKET

 

FLUSH

 

WITH

 

CEILING

WARNING: BE CAREFUL when installing the decorative fl ue and hood, they may have sharp edges.

CAUTION: DO NOT REMOVE the protective plastic fi lm covering the decorative fl ue (upper & lower).

!

3. Align the hood and center it above the hood mounting 

bracket. Gently lower the hood until it securely engages the 

bracket.

  Level the hood.

  With the hood hanging in place, secure it to the wall through 

both holes located in the inside upper back of hood using 

2 no. 8 x 1½” screws.

  Drill through both holes located in the inside lower back 

of hood using a 3/16” drill bit. Insert the included drywall 

anchors into the drilled holes (one for each hole). Secure 

the hood to the wall using 2 no. 8 x 3/4” screws and 

2 washers.

HD0380A

L

OWER

 

HOLES

 

LOCATION

B

ACK

 

OF

 

THE

 

HOOD

S

IDE

 

VIEW

Ø 

3/16” 

TYP

.

U

PPER

 

HOLES

 

LOCATION

!

H

ORIZONTAL

 

DISCHARGE

 

ONLY

:

 

4.  Position the blower on the higher (

A

) or lower (

B

) back wall 

discharge as determined previously.

  Using a 5/16” socket, or a Robertson or a Phillips no. 2 

screwdriver and the 4 previously removed screws, secure 

the blower to the hood.

 NOTE
  In order to ease installation, before mounting the blower, 

prepare the screw holes by screwing all 4 screws without 

the blower, then remove and mount the blower.

HD0387

A

B

R

IGHT

 

SIDE

 

MOUNTING

 

SCREW

LOCATION

5.  Plug the blower back in and plug hood power cord into the 

outlet.

Summary of Contents for 31130

Page 1: ...Models 31130 30 wide Stainless 31133 36 wide Stainless Range Hood Use Care Guide Installation Manual ENGLISH 09030 rev A SEARS CANADA INC Toronto Ontario M5B 2B8 www sears ca HB0108 ...

Page 2: ... explosive materials and vapors 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 4 Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated The motor will restart when it cools down If the motor continues to shut off and restart have the hood serviced 5 For best capture o...

Page 3: ... will continue to operate for 5 minutes and will stop automatically To cancel the delay function press the Delay OFF switch once again the blower will then work in normal mode NOTE The blower speed can be increased or decreased during Delay mode without starting another 5 minute cycle 1 5 HC0027 2 3 4 WARNING In order to prevent the risk of personal injury do not install a lamp identified for use ...

Page 4: ...INCLUDED WITH HOOD HR0051 120 V 50 W PAR16 with GU10 base shielded halogen lamp 2 per hood Sears Part No V05921 Ducting Accessories See Range Hood System on page 5 for Ducting Accessory Model Nos Optional flue extension for 10 ft ceilings model no 31131 HR0012 HR0010 HR0011 3 x 10 adapter damper for horizontal discharge HR0041 8 round adapter damper for vertical discharge in a separate box HR0042 ...

Page 5: ...d Elbow Ductwork Warranty Safety Cleaning Operation Service Parts Installation Broan Model 639 3 x 10 Standard Wall Cap Upper Decorative Flue Lower Decorative Flue Single Blower supplied with hood Adapter damper 8 round supplied with hood For vertical discharge Broan Model 401 Standard 3 x 10 Duct Adapter damper 3 x 10 supplied with hood For horizontal discharge Adapter dampers ...

Page 6: ...ntly when attached to long runs of duct As a point of reference this hood will function at approximately 80 of its rated air performance when 300 equivalent feet of 8 round ductwork is attached Use this chart to calculate the equivalent duct length of your system Note that 8 round is the minimum recommended duct size HR0046 8 in Round Elbow Equivalent length 10 ft Broan Model 639 3 x 10 Wall Cap E...

Page 7: ...izontal ductwork Refer to page 8 for more details SELECT INSTALLATION TYPE Warranty Safety Cleaning Operation Installation Service Parts 8 ROUND DUCT ROOF CAP 3 X 10 DUCT WALL CAP HOOD DECORATIVE FLUE HH0134A REFER TO CHART FOR DISTANCE ABOVE COOKING SURFACE Refer to illustrations below to locate duct opening according to discharge type chosen grey parts to be installed later CEILING HEIGHT MINIMU...

Page 8: ...k of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WIRING INSTALLATION Position the outlet within the space covered by the decorative flue Place the outlet at a maximum distance of 24 from where the cord exits fro...

Page 9: ...ontal discharge may be positioned on higher OR on lower back of the hood From outside the unit remove the knockout for the chosen discharge opening see illustrations beside HR0038 1 2 OR OR PREPARE THE HOOD Warranty Safety Cleaning Operation Installation Service Parts 1 Lay the hood on its back on a table Remove grease filters by lifting the metal latch tab 1 pushing down on the filter 2 and tilti...

Page 10: ... to the inner back of the hood once the hood is mounted on the wall 3 Uplug the blower HE0085 6 Secure the adapter damper to the back of the hood using 2 no 8 x 3 8 screws included Seal the adapter damper to the hood using metal foil duct tape NOTE The wall ducting must be properly prepared to receive the adapter Before performing the installation make sure the adapter fits easily in the duct NOTE...

Page 11: ... x 3 4 screws Ensure that the bracket is tight against the wall HD0377 C L CEILING SCREW LOCATIONS MOUNTING BRACKET FLUSH WITH CEILING WARNING BE CAREFUL when installing the decorative flue and hood they may have sharp edges CAUTION DO NOT REMOVE the protective plastic film covering the decorative flue upper lower 3 Align the hood and center it above the hood mounting bracket Gently lower the hood...

Page 12: ... lower flue as they are not needed HO0144 Both lower and upper flues are included with the hood but for a 10 foot ceiling discard the provided upper flue and use the optional extension flue part no 31131 purchase separately NOTE 2 Carefully slide in place decorative flue base notches end first between the shaded part and the exterior wall of the top of the hood HO0143 LOWER FLUE REAR NOTCH LOWER F...

Page 13: ... flue FINALIZE THE INSTALLATION This range hood must use 2 shielded halogen lamps 120 V 50 W PAR16 with GU10 base included Refer to page 4 for ordering information WARNING In order to prevent the risk of personal injury do not install a lamp identified for use only in enclosed fixtures WARNING In order to prevent the risk of personal injury the halogen lamps must cool down before removing them 1 T...

Page 14: ...GU10 2 2 10 05921 SHIELDED HALOGEN LAMP 120V 50W GU10 2 2 11 09022 TRANSFORMER 1 1 12 08582 INTERNAL BLOWER INCLUDING CAPACITOR 1 1 13 08783 CAPACITOR 1 1 14 18523 MICROMESH FILTERS 13 83 X 13 83 SET OF 2 1 1 15 09035 KENMORE ELITE LOGO 1 1 16 09014 HOOD MOUNTING BRACKET 1 1 17 08543 8 ROUND A DAPTER DAMPER 1 1 18 13296 3 X 10 ADAPTER DAMPER 1 1 09030 KENMORE ELITE INSTALLATION GUIDE 1 1 09027 PAR...

Reviews: