Kendrion Kuhnke Automation GmbH
Construction and Functionality
Vico MT
32
Power supply ratings
Supply voltage: +24 VDC ± 20 %
Current consumption: 0.15 A – 1 A
Power consumption: 3.6 W – 24 W
Internal fusing: 2 A fuse
Overvoltage category II, max. 300 V, on the primary side
Recommended PSU rating: Voltage/output power: 24 VDC / min. 30 W
Power supply fusing
The cord must have external protection against short circuit and overload triggering at max. 10 A, min. 60 V.
NOTE
Damage to connectors or cables by improper plugging or unplugging
Improper (un-)plugging may damage the cables, connectors and other parts of the system.
Always hold the lead by the connector to plug or unplug it.
Information
Actual power consumption depends on the display size, the brightness and the type and number
of active interfaces.