Mechanical installation
Kendrion INTORQ | BA 14.0217 | 07/2021
48
6.7.2
Installing the flange (variants: size 06 - 16)
The flange can be screwed to the end shield on the outer hole circle (for screw dimensioning, refer to the
table Characteristics: screw kit for brake assembly on separately screwed-on flange, Page 24).
NOTICE
Clearing holes for the screws in the end shield must be behind the threaded screw holes
in the flange. Without the clearing holes, the minimal rotor thickness cannot be used. The
screws must not press against the end shield.
Fig. 21:
Flange mounting for sizes 06 - 16
A
Screw
1)
B
Flange
C
Hub
D
End shield
1)
1. Make sure that there are clearing holes in the end shield at the positions of the screws in the stator
2. Place the flange against the end shield.
NOTICE
3. Use the three screws to screw the flange to the end shield.