Mechanical installation
Kendrion INTORQ | BA 14.0217 | 07/2021
47
6.6
Installing the friction plate (optional)
Fig. 20:
Mounting the friction plate
A
Stator
B
Rotor
C
Friction plate
D
End shield
1. Place the friction plate against the end shield. The lip edging of the friction plate must remain visible!
2. Align the hole circle along the screw-in holes.
6.7
Mounting the flange
6.7.1
Mounting the flange without additional screws
NOTICE
When dimensioning the thread depth in the end shield, be sure to take into account the
permissible wear distance (refer to Table Characteristics for air gap specifica-
tions, Page 23).
1. Place the flange against the end shield.
2. Align the hole circle along the screw-in holes.