Technical specifications
Kendrion INTORQ | BA 14.0217 | 07/2021
28
5.5
Operating times
The operating times listed here are guide values which apply to DC switching with rated air gap s
LN
, warm
coil and standard characteristic torque. The given operating times are average values and subject to varia-
tions. The engagement time t
1
is approximately 8 to 10 times longer for AC switching. ...
t
t
M
t
2
t
12
t
11
t
1
M
dyn
U
0.1M
dyn
Fig. 4:
Operating/switching times of the spring-applied brakes
t
1
Engagement time
t
11
Delay time during engagement
t
2
Disengagement time (up to M = 0.1 M
dyn
)
t
12
Rise time of the braking torque
M
dyn
Braking torque at a constant speed of rotation
U
Voltage
Size
Rated torque
M
K
Operating times
1)
DC-side engagement
Disengaging
t
11
t
12
t
1
t
2
[Nm]
[ms]
[ms]
[ms]
[ms]
06
4
15
13
28
45
08
8
15
16
31
57
10
16
28
19
47
76
12
32
28
25
53
115
14
60
17
25
42
210
16
80
27
30
57
220
18
150
33
45
78
270
20
260
65
100
165
340
25
400
110
120
230
390
Tab. 9:
Switching energy - operating frequency - operating times
1)
These operating times are specified for usage of Kendrion INTORQ bridge/half-wave rectifiers and coils with a con-
nection voltage of 205 V DC at s
LN
and 0.7 I
N
.