Minimum bending radius for the brake connection cable
Size
Wire cross-section
Minimum bending radius
06
AWG 20
27.5 mm
08
10
12
14
16
18
45.6 mm
20
25
Tab. 14:
Minimum bending radius for the brake connection cable
7.7
Bridge/half-wave rectifier (optional)
BEG-561-
□□□
-
□□□
The bridge-half-wave rectifiers are used to supply electromagnetic DC spring-applied brakes which are ap-
proved for use with such rectifiers. Other use is only permitted with the approval of Kendrion INTORQ.
Once a set overexcitation period has elapsed, the bridge-half-wave rectifiers switch over from bridge recti-
fication to half-wave rectification.
Terminals 3 and 4 are in the DC circuit of the brake. The induction voltage peak for DC switching (refer to
the circuit diagram DC switching at the motor – fast engagement, Page 57) is limited by an integrated
overvoltage protection at terminals 5 and 6.