Mechanical installation
Kendrion INTORQ | BA 14.0217 | 07/2021
49
4. Check the height of the screw heads. The screw heads must not be higher than the minimum rotor
Notice
When mounting the flange, the various size classes must be distinguished: sizes 06 – 16, 18 –
20 and 25 are mounted differently.
6.7.3
Installing the flange (variants: size 18 - 20)
NOTICE
¾
Clearing holes for the screws in the end shield must be behind the threaded screw
holes in the flange. Without the clearing holes, the minimal rotor thickness cannot be
used. The screws must not press against the end shield.
¾
For sizes 18 and 20, the mounting surface threading must be angled at 30° to the cen-
ter axis to the hand-release lever.
Fig. 22:
Flange mounting for sizes 18 – 20
1)
1. Place the flange against the end shield.