14 – Pro 3200 Evolution, Pro 4200 Evolution, Pro 5200 Evolution/0109
©
COPYRIGHT
KEMPPI
OY
9. TECHNICAL DATA AND TERMS
OF GUARANTEE
9.1. TECHNICAL DATA
Pro 3200 Evolution
Pro 4200 Evolution
Pro 5200 Evolution
Mains voltage
3~50/60 Hz
400 V±10 %
400 V±10 %
400 V±10 %
Rated power
80 % ED
420 A / 19,7 kVA
520 A / 26,6 kVA
100 % ED
320 A / 13,3 kVA
400 A / 18,6 kVA
440 A / 20,0 kVA
Connection cable/
fuse delayed
4 x 6 S - 5 m / 25 A
4 x 6S - 5 m /35 A
4 x 6S - 5 m / 35 A
Max. welding voltage 40
0
C
80 % ED
420 A / 36,8 V
520 A / 40,0 V
100 % ED
320 A / 32,8 V
400 A / 36 V
440 A / 37,6 V
Max. welding voltage 20
0
C
100 % ED
320 A / 32,8 V
420 A / 36,8 V
490 A / 39,6 V
Welding current range
MMA
10 A ... 320 A
10 A ... 420 A
10 A ... 520 A
TIG
5 A ... 320 A
5 A ... 420 A
5 A ... 520 A
MIG
10 V ... 36 V
10 V ... 41 V
10 V ... 45 V
Max. welding voltage
46 V / 300 A
46 V / 400 A
50 V / 500 A
Open circuit voltage
65 V
n. 65 V
n. 65 V
Open circuit power
< 75 W
< 75 W
< 75 W
Efficiency
at nominal values
appr. 85 %
appr. 85 %
appr. 85 %
Power factor
at nominal values
appr. 0,93
appr. 0,93
appr. 0,93
Storage temperature
range
-40 ... +60
0
C
-40 ... +60
0
C
-40 ... +60
0
C
Operating
temperature range
-20 ... +40
0
C
-20 ... +40
0
C
-20 ... +40
0
C
Temperature class
H (180
0
C) / B (130
0
C) H (180
0
C) / B (130
0
C) H (180
0
C) / B (130
0
C)
Degree of protection
IP 23 C
IP 23 C
IP 23 C
Extemal dimensions
length
530 mm
530 mm
530 mm
width
230 mm
230 mm
230 mm
hight
520 mm
520 mm
520 mm
Weight
37 kg
41 kg
48 kg
Voltage supply for
auxiliary devices
50 V DC
50 V DC
50 V DC
X 14, X 15
fuse 6,3 A delayed
fuse 6,3 A delayed
fuse 6,3 A delayed
Voltage supply for cooling unit
PROCOOL 10
1~, 230 V / 250 VA
1~, 230 V / 250 VA
1~, 230 V / 250 VA
X 16
fuse 1,0 A delayed
fuse 1,0 A delayed
fuse 1,0 A delayed