7.3. UNDER- AND OVERVOLTAGES IN THE MAINS SUPPLY
Primary circuits of machine are protected against sudden, transient overvoltages.
Machine is designed to withstand 3 x 440 V voltage continiously (see technical data). See to
it that voltage is kept within admissble limits especially when mains supply is taken e.g. from
combusition engine generator.
If the mains has undervoltage (under approx. 300 V), machine control stops to operate automa-
tically.
7.4. LOSS OF A PHASE IN THE MAINS SUPPLY
Loss of a phase causes noticeable poorer welding properties than normally or the machine
doesn’t get started at all. Loss of a phase can be due to following:
- blowing of mains supply fuse
- defective mains cable
- bad connection of mains connection cable on terminal block or plug of machine