KEMPER ProfiMaster Instruction Manual -
EN
Product number: 150 2464
- 58 -
rev.:
2
Technical changes and errors reserved.
Status as of: 05/2015
6.3 Adjusting the position of the extraction nozzle
The exhaust arm, or exhaust nozzle respectively, are designed to ensure easy
manual adjustment and a closer approach. At the same time, the exhaust nozzle is
automatically kept in the set position. Furthermore, both the exhaust nozzle and the
exhaust arm rotate by 360 degrees so they can be adjusted to almost any position.
To ensure the sufficient suction of welding fumes, it is important for the exhaust
nozzle to be in the correct position all the time. The correct position is shown in the
following picture.
•
Adjust the position of the exhaust arm so that the exhaust nozzle is located at
an angle and about 25 cm above the point of welding.
•
The exhaust nozzle must be set so that, with regard to the thermally
conditioned movement of welding fumes and suction reach, it safely collects
all welding fumes.
•
Always place the exhaust nozzle close enough to the relevant welding point.
6.4 Putting into operation
•
Switch the device using the button identified with "0" and "I" symbols.
•
The fan will start-up and the green indicator light on the instrument switch
signals trouble-free operation.
•
The exhaust nozzle must additionally be adjusted, depending on the stage of
the procedure.
CAUTION
The incorrect placement of exhaust nozzle or insufficient suction power do
not guarantee the sufficient suction of the air containing hazardous
substances via the exhaust nozzle. Hazardous substances can thus reach
the user's respiratory system and lead to health injury!
Picture 5, Adjusting the position of the extraction nozzle