Kemlan wood heaters carry a warranty on the 6mm firebox for a period of ten (10) years.

2. 

This warranty also covers other components of the heater for a period of one (1) year.  

 

These components include the baffle plate, handle assembly and fan.

3. 

Kemlan’s warranty covers the wood heaters against defects in materials and manufacture.

4. 

THIS WARRANTY DOES NOT COVER - 

4.1 

Failure to comply with manufacturer’s operation instructions.

4.2 

Normal wear and tear or damage caused by incorrect installation.

4.3 

Any form of rust and/or corrosion to the painted finish of the heater.

4.4 

Damage to the glass in the door, if the damage is caused by impact or misuse.

4.5 

The cost of collection and delivery of the wood heater and/or parts.

4.6 

Damage caused by water ingress.

4.7 

Cost of removal of defective heater or re-installation of replacement heater.

5. 

CLAIMS - 

5.1 

(i)  Kemlan will provide a full replacement of the heater in the first five years after installation.

(ii) Replacement in the subsequent five years (i.e. sixth to tenth year after installation will be on the 

following basis.

Owner will pay twenty percent of purchase price if the claim is made in the sixth year and a further ten percent 

per year in every subsequent year to a maximum of fifty percent of the purchase price of the heater.

5.2 

Replacement of heater subject to all conditions in section four of warranty.

5.3 

Should any defects occur, contact the Kemlan distributor from whom you purchased the heater.

5.4 

Under this warranty the defective parts will be repaired or replaced by Kemlan’s option, free of charge.

6. 

The fireplace installation must comply with the relevant local statutes, ordinances, regulations

 

and by-laws.

PLEASE COMPLETE AND RETAIN THIS SECTION FOR YOUR RECORDS

Purchased from:  .......................................................................................................

Address:  ....................................................................................................................

Date of Purchase:  ......................................................................................................

WARRANTY

Summary of Contents for XL

Page 1: ...TIONS WITH THE UNIT ON COMPLETION 1x900mm LENGTH HEATSHIELD OR DECROSHIELD MUST BE FITTED TO THE FLUE TO ACHIEVE CLEARANCES TO HEAT SENSITIVE MATERIALS 10 YEAR FIREBOX WARRANTY The firebox is covered by a 10 year warranty Other parts are covered by one year limited warranty Head Office Telephone Facsimile Website Business hours Email 13 French Avenue Brendale Queensland 4500 07 3263 8448 07 3263 6...

Page 2: ... When in use some parts may become hot A suitable fireguard is recommended where the very young elderly or infirm are concerned CONSTRUCTION 6 8mm heavy duty steel firebox fully welded 25mm thick firebrick lined floor 19mm ceramic lined sides and baffle PERFORMANCE Heating capacity 220 320m2 23 33 squares Peak heat output 21 6kW Average output 2 0g kg Average efficiency 61 Glass viewing area 602mm...

Page 3: ...l flues should be trimmed level Pop rivet or screw brackets to the outside of the outer casing A FLAT CEILING A Outer casing may be painted without priming Run a bead of silicon down seam of outer casing to ensure against leaks All casing flue pipes must be connected via pop rivets supplied by installer Stainless steel flue pipe All flue pipes must be connected via pop rivets supplied by installer...

Page 4: ...cket supplied 1000mm minimum distance above roof line Outer casing may be painted without priming Run a bead of silicon down seam of outer casing to ensure against leaks All casing flue pipes must be connected via pop rivets supplied by installer Stainless steel flue pipe All flue pipes must be connected via pop rivets supplied by installer 10 8 6 Roof flashing supplied by contractor NOTE When dec...

Page 5: ...LOW MEDIUM LOW 3000 3000 3000 3000 or less 3000 or less 1000 min if clear within 3000 of top of flue Increase from 1000 min until clear within 3000 of top of flue More than 3000 More than 3000 600 min 600 min Any nearby structure Increase as necessary until nothing within 3000 of flue top INSTALLATION INSTRUCTIONS MINIMUM HEIGHT OF FLUE SYSTEM EXIT INSTALLATION TO COMPLY WITH AS NZS 2918 ...

Page 6: ...6 CERTIFICATE GOES HERE ...

Page 7: ...Don t touch the surface It will be soft and gummy during this paint curing phase Once cured it will not be soft again CURE WITH 3 FIRES Most stoves cure with 3 burns The first two 2 should be 250 F for 20 minutes or about half a normal fire Let the stove cool down between burns The last fire should be 500 F to 700 F for at least 45 minutes The point being cure slowly without a hot fire Stoves with...

Page 8: ...en it may be returned to its desired setting 6 To set the fire for overnight burn two thirds fill the firebox with hardwood and fully open the air inlet Once the fire is burning well the air inlet control should be shut down approximately three quarters of its travel Setting the air inlet control may be varied to suit your particular requirements and the quality and size of your firewood Remember ...

Page 9: ...higher heat production than wet or green wood The difference between the amount of heat produced by dry wood and green wood is so great that a dry softwood of good grade will produce more heat than green hardwood Green white ash for instance is not as good a fuel as dry tamarack The reason for the superiority of dry wood is easy to understand Heat cannot be produced until moisture has been driven ...

Page 10: ...e heater or re installation of replacement heater 5 CLAIMS 5 1 i Kemlan will provide a full replacement of the heater in the first five years after installation ii Replacement in the subsequent five years i e sixth to tenth year after installation will be on the following basis Owner will pay twenty percent of purchase price if the claim is made in the sixth year and a further ten percent per year...

Reviews: