30
Buzzer Error Codes
Table 1: Error Codes
Code
Explanation
Solution
1,1
¤
¤
Automatic error
identification
1. Wrong wiring of motor phase line or hall.
Please suspend the motor when enable
Auto-Identify function.
1,2
¤
¤¤
Over voltage error
2. Battery voltage is too high for the controller.
Check battery volts and configuration.
3. Regeneration over-voltage. Controller will have
cut back or stopped regen.
4. This only accurate to
±
2% upon Overvoltage
setting.
1,3
¤
¤¤¤
Low voltage error
1. The controller will clear after 5 seconds if battery
volts returns to normal.
2. Check battery volts & recharge if required.
1,4
¤
¤¤¤¤
Reserved
2,1
¤¤
¤
Motor did not start
Motor did not reach 25 electrical RPM within 2
seconds of start-up. Hall sensor or phase wiring
problem.
2,2
¤¤
¤¤
Internal volts fault
1. Measure that B+ & PWR are correct when
measured to B- or RTN.
2. There may be excessive load on the +5V supply
caused by too low a value of Regen or throttle
potentiometers or incorrect wiring.
3. Controller is damaged. Contact Kelly about a
warranty repair.
4. If this error code occurs,the relay function on plin9
will be deactivated.
•
Configuration software will be regularly updated and published on the website. Please
Update your Configuration Software regularly. You must uninstall the older version
before updating.
•
Please try to use Identify function for motor and hall sensors in the user program
Summary of Contents for KLS-H
Page 2: ...Kelly KLS H Brushless Motor Controller User s Manual V1 10 Rev 1 10 Jun 2017 ...
Page 3: ......
Page 11: ...8 Figure 2 KLS7245H mounting holes dimensions dimensions in millimeters ...
Page 12: ...9 Figure 3 KLS7250H mounting holes dimensions dimensions in millimeters ...
Page 13: ...10 Figure 4 KLS7275H mounting holes dimensions dimensions in millimeters ...
Page 14: ...11 Figure 5 KLS72xxx 8080H KLS96xxx 8080H mounting holes dimensions dimensions in millimeters ...