Field assembly & commissioning
smart slider - Field assembly & commissioning
05. Explanation LCD info screen
5.1 Description display ‘cockpit’
position in cm
(closed position = 0)
speed
(cm/sec)
motor
consumption in Amp.
LED
= open position
= window closed
= slow down active
= square spot ( )
INFO – SIGNALING – DISPLAY
If ‘square DOT’ beside character
→
System = active
(n.c. contact, has to be illuminated when active)
Following this display…
Position is now at
211 cm
from close position, last speed was
4 cm/s
, and motor consumption of
2 A
.
S
afety
o
pen is ok,
S
afety
c
lose is ok,
L
imit
s
witch left is activated, also limit switch slow speed,
L
imit
s
witch right is ok.
It’s mode is
A
utomatic (with automatic closure active), a
-
single use motorisation, a
L
eft opening system configuration and a
C
lose command is given…
commando‘s
O
Open
C
Close
S
Stop
p
Pedestrian opening
master slave
-
single use
M
Master
S
Slave
Y
Master synchro
operation modus
a
Auto mode
A
Auto mode & auto close active
P
Puls mode (death man)
S
Semi-Automatic mode
limit switches
L >
Limit switch right (L>
= limit switch high)
L s
Lock signal ( o = open, c = closed)
L <
Limit switch left (L >
= limit switch high)
safety‘s
So
Safety Open (So
= safety open)
Sc
Safety Close (So
= safety close)
position motor
l
motor left position
r
motor right position
sliding direction
L
Left opening system
R
Right opening system
.