- 15-
Fig.3.1.4
Incorrect installation position
(light curtain is a little lower, the hand can stretch into it upside the highest beam)
3.1.3
Settings for auxiliary protection measures
When the horizontal distance between the safety light curtain plane of the safety light curtain and
the front end of the die exceeds 400 mm, additional auxiliary photoelectric or protective bars should
be installed to prevent the operator from entering the inside of the light curtain plane, as shown in
Figure 3.1.5. When the distance is less than 400mm, Auxiliary photoelectric or protective fence and
other safety measures may be taken.
Fig.3.1.5
Incorrect installation position
( light curtain is too far from the die orifice, operators could enter danger zone )
Warning
A. The height position is one of the necessary conditions to ensure the protection function of
the safety light curtain. The installation must ensure that the height is in the correct position.
B. When the machine tool slides, we must overhaul the machine tool timely. Otherwise, even
if the safety light curtain is installed in the right position, it will not ensure safety.
C. If it is necessary to replace the mold in the use process, we must adjust the position of
safety light curtain according to the above two items of requirements.
D. The company is not liable for any personal injury caused by the wrong location of the
installation.