background image

Foreword

Thank you for choosing KS06M safety light curtain!

KS06M safety light curtain is suitable for automation and machining field.

The device only protects the rectangular light curtain area between the emitter and the

receiver. If its installation position is incorrect, or the operation does not follow the

instructions and related safety rules, or the equipment actuator breaks down, the

device may not be able to play the protective role. Therefore, before installing this

device, please read the instructions carefully and fully understand the relevant items,

especially the "warning", "attention" and other contents; in use, please correctly

understand the performance of the safety light curtain and operate in strict accordance

with the instructions and related safety rules for safety light curtain.

The instructions only introduce the application of KS06M safety light curtain in the

pressure machine. The instructions are only used for reference when the safety light

curtain is used in other occasions.

As a result of the technical update of the product, when the product is inconsistent

with the relevant contents provided in the instructions, the material object shall

prevail. We will release the change notice on the company's website in time. Please

log in http://www.sdkeli.com for verification.

The instructions are interpreted by Shandong Keli Opto-electronic Technology Co.,

Ltd.. When reading or using the instructions, please contact us if there are any

uncertainties.

Summary of Contents for KS06M

Page 1: ...tly understand the performance of the safety light curtain and operate in strict accordance with the instructions and related safety rules for safety light curtain The instructions only introduce the...

Page 2: ...Product Introduction 4 2 1 General 4 2 2 Specification 4 2 3 Selection Instruction 5 2 4 Function and Appearance 6 2 5 Part Dimensions 7 2 6 Technical Parameters 10 Part 3 Installation Wiring and Comm...

Page 3: ...procedure Warning This is a safety warning label The content of the label is very important Operators must strictly implement the safety information in the label to avoid possible personal injury Not...

Page 4: ...se shall be responsible for the necessary training of the employees Training contents include Installation adjustment use and maintenance of equipment and related safety systems KS06M safety light cur...

Page 5: ...ic error or control loop failure does not result in a risk of failure of KS06M safety light curtain 1 3 Product Support Please operate KS06M safety light curtain according to the requirements of the i...

Page 6: ...accuracy is 14mm it may be used to protect the fingers It is applicable to the automation field and machining field KS06M safety light curtain provides protection against dangerous areas at different...

Page 7: ...han the width of the table board needs to be protected Notice When the actual protection table board width is larger than the rated protection length it may lead to unstable system work or shorten ser...

Page 8: ...f NPN output form We shall not be liable for any personal injury caused by the short circuit between the output cable and other circuits 2 4 Function and Appearance l Safety light curtain KS06M safety...

Page 9: ...5m Type C 1 5m 9 5m When the configuration of the standard cable length cannot meet the requirements it should be customized when ordering The connection of each connection point of the transmission...

Page 10: ...8 LCS vibration reducer Bracket arm LCS JZ mounting bracket LCS vibration mounting bracket Steel pipe Fig 2 5 1 Detail drawing of major parts...

Page 11: ...5 480 750 775 790 1000 1085 1100 1500 34 495 510 750 825 840 1200 1155 1170 1500 36 350 365 750 525 540 750 875 890 1200 1225 1240 1500 38 555 570 750 925 940 1200 1295 1310 1500 40 390 405 750 585 60...

Page 12: ...1500V in 60s Beam spacing 10mm 15mm 25mm 35mm Detection capability 14mm 20mm 30mm 40mm Protection length Series A 0 3m Series B 0 6m Series C 2 9m Output characteristics NPN type When transmitting lig...

Page 13: ...and high position In order to ensure the safety of the operator the installation position of the safety light curtain must conform to the requirements of safety distance and height otherwise there is...

Page 14: ...way from the light curtain to the slider of the pressure machine reaching the bottom dead center s It can be calculated according to formula 3 or measured in practice Determination of K value l When t...

Page 15: ...g the safety distance Detection accuracy mm Additional distance C mm Stroke start of safety light curtain 14 0 Allowed 14 20 80 20 30 130 30 40 240 Not allowed 40 850 Warning The safety distance is on...

Page 16: ...that required light curtain protection height by relevant safety standards Fig 3 1 1 Correct installation position Fig 3 1 2 Incorrect installation position light curtain is too close to the die orifi...

Page 17: ...afety measures may be taken Fig 3 1 5 Incorrect installation position light curtain is too far from the die orifice operators could enter danger zone Warning A The height position is one of the necess...

Page 18: ...cket LCS vibration reducer Emitter Receiver Fig 3 2 1 Common front mounting PZ A The installation position of emitter and receiver should be determined according to the calculated safety distance and...

Page 19: ...mitter and receiver are directly installed on the machine body with the ordinary mounting bracket It is generally applicable to the closed pressure machine with framed structure Installing form as sho...

Page 20: ...2 3 Clamping mounting JZ select back clamping or side clamping It refers to the installation mode that the emitter and receiver are directly installed on the machine body with the clamping mounting b...

Page 21: ...ne and four column hydraulic press Installing form as shown in Fig 3 2 4 The installation steps are as follows A Install pipe mounting bracket l According to the safety distance and height position de...

Page 22: ...height and horizontal corner to make them parallel and aligned G After commissioning fasten all screws Emitter Receiver LCS vibration reducer LCS pipe mounting fixing clamp M4 20 cross recessed screw...

Page 23: ...ovides two output forms namely PNP output or NPN output The normal indicator green light is on when the light curtain transmits light on the light curtain The output transistor is connected and has th...

Page 24: ...ment should be consistent with the forecast to ensure the accuracy Part 4 Maintenance Before the formal working check the working state of light curtain The work may be conducted when normal The abnor...