5-12
Troubleshooting
KPCI-PIO96 User’s Manual
2. Turn OFF the host computer.
3. Remove the KPCI-PIO96 board.
4. Insert the loop-back test connector, prepared in step 1, into the board connector designated in
Table 5-3. (For connector locations, see Figure 3-2.) If the loop-back circuit is connected via
a ribbon cable, feed the cable out through the slot in the mounting bracket.
Table 5-3
Where to insert the loop-back connector
5. Reinstall the board in the PCI slot.
6. Turn ON the host computer and boot Windows 95®.
7. Click the Windows 95/98/NT Start tab.
8. Start the PIO Control Panel as follows:
a.
In
the
Start menu, click Programs.
b.
Find
the DriverLINX
➧
Test Panels folder, under which you should find the PIO
Panel entry.
c. Click on the PIO Panel entry.
The
PIO Control Panel should appear. See the example in Figure 5-3.
If you are testing this group of A, B, and
C ports:
Then plug the loop-back connector into
this KPCI-PIO96 I/O connector
Port group 0
J102
Port group 1
J103
Port group 2
J104
Port group 3
J105