8-3
If your board is not operating properly after using the information in
Table 8-1, continue with the next two sections to further isolate the
problem.
Data appears to be
invalid
The most common cause of this
problem is that the I/O bus speed
is in excess of 8 MHz.
Reduce I/O bus speed to a maximum of
8 MHz (to change the I/O bus speed, run
BIOS setup). See the documentation for
your computer for instructions on
running BIOS setup.
An open connection exists.
Check wiring to screw terminal.
Another system resource is using
the specified base address.
Reconfigure the base address of the
DDA-06
board; refer to page 3-3 for
more information. Check the I/O
assignments of other system resources
and reconfigure, if necessary.
Computer does not
boot.
Board not seated properly.
Check the installation of the board.
The base address setting of the
DDA-06
board conflicts with
that of another system resource.
Check the base address settings of your
system resources; each address must be
unique.
The power supply of the host
computer is too small to handle
all the system resources.
Check the needs of all system resources
and obtain a larger power supply.
System lockup
A timing error occurred.
Press
[Ctrl] + [Break]
.
Table 8-1. Troubleshooting Information (cont.)
Symptom
Possible Cause
Possible Solution