4-2
Troubleshooting
Model 2750 Multimeter/Switch System Service Manual
Introduction
This section of the manual will assist you in troubleshooting and repairing the Model
2750. Included are self-tests, test procedures, troubleshooting tables, and circuit descrip-
tions. It is left to the discretion of the repair technician to select the appropriate tests and
documentation needed to troubleshoot the instrument. Refer to the disassembly proce-
dures in
and the parts lists in
for further information.
WARNING
The information in this section is intended only for qualified service per-
sonnel. Do not perform these procedures unless you are qualified to do so.
Some of these procedures may expose you to hazardous voltages that
could cause personal injury or death. Use caution when working with haz-
ardous voltages.
The metal shield located on the motherboard is at analog LO potential and
may have hazardous voltages. To avoid a possible shock hazard, connect
the metal shield to chassis ground before servicing.
Repair considerations
Before making any repairs to the Model 2750, be sure to read the following
considerations.
CAUTION
The PC boards are built using surface mount techniques and require spe-
cialized equipment and skills for repair. If you are not equipped and/or
qualified, it is strongly recommended that you send the unit back to the
factory for repairs or limit repairs to the PC board replacement level. With-
out proper equipment and training, you could damage a PC board beyond
repair.
•
Repairs will require various degrees of disassembly. However, it is recommended
that the Front Panel Tests be performed prior to any disassembly. The disassembly
instructions for the Model 2750 are contained in
•
Do not make repairs to surface mount PC boards unless equipped and qualified to
do so (see previous CAUTION).
•
When working inside the unit and replacing parts, be sure to adhere to the handling
precautions and cleaning procedures explained in
.
•
Many CMOS devices are installed in the Model 2750. These static-sensitive
devices require special handling as explained in
•
Whenever a circuit board is removed or a component is replaced, the Model 2750
must be recalibrated. See
for details on calibrating the unit.
Summary of Contents for 2750
Page 13: ...1 PerformanceVerification...
Page 48: ...1 36 Performance Verification Model 2750 Multimeter Switch System Service Manual...
Page 49: ...2 Calibration...
Page 74: ...2 26 Calibration Model 2750 Multimeter Switch System Service Manual...
Page 75: ...Routine Maintenance 3 RoutineMaintenance...
Page 86: ...3 12 Routine Maintenance Model 2750 Multimeter Switch System Service Manual...
Page 87: ...Troubleshooting 4 Troubleshooting...
Page 111: ...Disassembly 5 Disassembly...
Page 118: ...5 8 Disassembly Model 2750 Multimeter Switch System Service Manual...
Page 119: ...Replaceable Parts 6 ReplaceableParts...
Page 135: ...Specifications A AccuracyandOptimization...
Page 140: ...A 6 Accuracy and Optimization Model 2750 Multimeter Switch System Service Manual...
Page 141: ...Calibration Reference B CalibrationReference...
Page 167: ...Calibration Program C CalibrationProgram...
Page 178: ......
Page 179: ......