Keith LeakProof III Owner'S Manual Download Page 13

OWNER / OPERATOR MANUAL 

LeakProof III

        

 

 

 

 

 

DOC06436  Rev B

!!NOTE!!  Make sure trailer doors are open BEFORE

 starting the floor or serious damage may occur.

 

 Operation of Your LEAKPROOF III Drive                            

 

 

LEAKPROOF  III DRIVE

OPERATION OF YOUR KEITH

®

LEAKPROOFIII DRIVE

UNLOADING

 

1.To unload with your KEITH LEAKPROOF III Drive, engage the P.T.O. then bring the tractor    

 

   engine up to the predetermined unloading RPM.

 

2.Pull the control valve handle all the way out. (See Diagram A.)

 

3.Make sure that the ball valve, located between the pressure and return lines, is in the closed   

 

   position. (See Diagram B.) This ball valve is used for the emergency shut-off. Your trailer 

 

   

floor

 

should

 

now

 be 

operating.

 

4.To

 

stop

 

the

 

floor

 

at

 

any

 

time

 

during

 

the

 

loading

 

or

 

unloading

 

process,

 

switch

 

the

 

ball

 

valve

 

to

      

 

   the open position. (See Diagram B.)

LOADING

 

1.To manually load with your bi-directional KEITH LEAKPROOF III Drive, simply turn 

 

   the control valve handle parallel to the ground and push it under the valve body. 

 

   (See Diagram A.) Then follow instructions 1,3 and 4 listed above.

!!NOTE!!

Make sure the trailer door is open BEFORE

starting the floor or the trailer door will be damaged.

Diagram A: Control Valve

(Manual Version)

Diagram B: Ball Valve

(View in 

Closed Position.

 Push handle 

to the 

curb side to open.

)

[View is from beneath the trailer.]

Diagram A: Control Valve

(Manual Version)

Diagram B: Ball Valve

(View in 

Closed Position.

 Push 

handle to the 

curb side to open.

)

[View is from beneath the trailer.]

 

Speed of Floor in Relation to Engine RPM 

 

 

 

LEAKPROOF  III DRIVE

SPEED OF FLOOR IN RELATION TO ENGINE RPM

With a Fuller 13 or 15 speed transmission, a bottom mount 118% series 442/489 Chelsea power take 

off, and a Commercial p-51 pump with a 2 1/2” gear, the tractor unload RPM in relation to 

floor

 move

-

ment is as follows*.

TRUCK RPM

950 RPM

1270 RPM

1430 RPM

1750 RPM

1900 RPM

PUMP OUTPUT

30 gallon

40 gallon

45 gallon

55 gallon

60 gallon

FLOOR MOVEMENT

7.3 ft/minute

9.8 ft/minute

11.1 ft/minute

13.3 ft/minute

14.6 ft/minute

*Above 

specifications

 are for KEITH

® 

LEAKPROOF III Drive units with 80mm bore cylinders. These 

are approximate feet per minute only and should be used strictly as a guide.

1” Female Quick Coupler

2404-16-16

Straight

10643-16 Crimp

Hose Fitting

1” Pressure Hose

2603-16-16-16

Tee

10643-12 Crimp

Hose Fitting

2404-12-12

Straight

2406-12-16

Straight

10643-16 Crimp

Hose Fitting

1” Pressure Hose

6400-16-16

Straight 

P.T.O.

Pump

W43-32-32 Flange

Elbow Street 2”

3/4” Pressure

Relief Hose

King Nipple 2”

2” Suction 

Hose

5406-12 Socket Pipe Plug

Relief Valve

1” Rubber Shock Mount

Slight Gauge

Filler Screen Assy.

Baffle

Truck Frame

2404-20-20

Straight

2404-20-24

Straight

10643-20 Crimp

Hose Fitting

1 1/4” Filter to Tank

Return Hose

Filter Heads

10643-16 Crimp

Hose Fitting

2404-16-16

Straight

1’ Male Quick Coupler

1” Trailer to Filter

Return to Hose

Filter Elements

10643-12 Crimp

Hose Fitting

2404-12-12

Straight

Summary of Contents for LeakProof III

Page 1: ...OWNER OPERATOR MANUAL Released 2023 04 17 DOC06436 Rev B 2023 KEITH Manufacturing Co All Rights Reserved KEITH KEITH logo and WALKING FLOOR are registered trademarks of KEITH Manufacturing Co Equipme...

Page 2: ...al Wet Kit Specifications 2 2 2 Floor to Wet Kit Diagram 3 2 3 Floor Speed vs Pump Flow Rate 4 3 0 Operation 5 3 1 Oil Flow Diagram 5 3 2 Start Up 6 3 3 Standard Operating Procedures 6 4 0 Maintenance...

Page 3: ...ithWalkingFloor com In addition we have provided general information on the type of hydraulic wet kit that will be needed to operate your system Please contact a KEITH sales representative or visit ou...

Page 4: ...Manufacturing Co s sole liability under this warranty and the owner s sole and exclusive remedy is limited to repair or replacement of the defective part s at a facility authorized by KEITH Manufactur...

Page 5: ...excessive heat over 140 F 60 C due to a bad hydraulic pump on the truck or hydraulic wet kit or improper operation of the unloading system for example not fully opening and closing the ball valve Def...

Page 6: ...Name _______________________________________________________________ Address ____________________________________________________________________________ City State Prov _____________________________...

Page 7: ...e floor with the doors closed 2 DO NOT Stand behind the trailer or in the discharge area 3 DO NOT Make adjustments to the unloading mechanism with the floor operating 4 DO NOT Operate the unloader whe...

Page 8: ...er head DF 15 25 MF 2215 25 0 2 0 Filter element LE 10 or LE 30 The filter element should be changed after 6 hours initially and then every 6 months thereafter This may vary with the operating environ...

Page 9: ...pump TRAILER 1 Female quick coupler to be on return line Line from switching valve port stamped RES 2 Male quick coupler to be on pressure line Line to switching valve port stamped PUMP If you have an...

Page 10: ...tractor unload RPM in relation to floor movement is as follows Truck RPM Pump Output Floor Movement 950 RPM 30 gallon 7 3 ft minute 1270 RPM 40 gallon 9 8 ft minute 1430 RPM 45 gallon 11 1 ft minute 1...

Page 11: ...ylinders as shown in Blocked by check valve Note Phase 2 requires more pressure than phase 1 Phase 3 The 2 cylinder completes its full stroke opening the check valve and allowing the oil in the 3 cyli...

Page 12: ...check will help determine this information Be sure that your entire wet kit system meets the requirements of the hydraulic wet kit specifications in this booklet 3 3 Standard Operating Procedures UNL...

Page 13: ...SPEED OF FLOOR IN RELATION TO ENGINE RPM With a Fuller 13 or 15 speed transmission a bottom mount 118 series 442 489 Chelsea power take off and a Commercial p 51 pump with a 2 1 2 gear the tractor unl...

Page 14: ...maintenance program as loose floor bolts will cause serious damage to floor slats After the first week of operation you must check and tighten the lower cross drive clamps that fasten the cross drive...

Page 15: ...ll rear position and the switching valve has switched you may not have enough oil pressure Less pressure is required to move the load than to pull the slats 1 3 at a time under the load 5 2 Check Valv...

Page 16: ...lve at the rear end of the cylinder 2 has malfunctioned Replace the check valve Specific trouble All cylinders extend together toward the rear while loading Solution The control valve is bypassing or...

Page 17: ...arts list in the Parts Catalog to identify parts by given numbers Replacing a Check Valve LEAKPROOF III DRIVE REPLACING A CHECK VALVE Replacing a KEITH LEAKPROOF III Drive check valve is a simple proc...

Page 18: ...loor com Toll Free 800 547 6161 Phone 1 541 475 3802 6 0 Contact Information KEITH Manufacturing Co World Headquarters USA 401 NW Adler St P O Box 1 Madras OR 97741 Toll Free 800 547 6161 Phone 1 541...