T-506 User Manual Version 3.2 | 9
2.6
Technical Data Sheet
Parameter
Parameter Value
Fault fixed point accuracy
≤
0.2m
Detector dynamic range
•
Sound channel
•
Magnetic field channel
>110dB
>110dB
Operating frequency range
•
Sound channel
•
Magnetic field channel
100Hz
—
1500Hz
160Hz
—
50000Hz
Sound channel filter
•
No filtering
•
Low-pass filtering
•
Bandpass filtering
•
High-pass filtering
100Hz
—
1500Hz
100Hz
—
400Hz
150Hz
—
600Hz
200Hz
—
1500Hz
Power supply
•
Detector
•
Tablet PC
Lithium battery 2200mAh
Lithium polymer battery 2x 2600mAh
Charging
•
Detector
•
Protection level
•
Tablet PC
Input: 100-240V - 50/60Hz
Output: 8.4V/1.0A
Class II
Input: 100-240V - 50/60Hz
Output: 5.0V/2A
On-site continuous working hours
•
Detector
>
12h
Weight
•
Detector
•
Tablet PC
2.0kg (with handle)
1.2kg (including harness)
Volume
•
Detector
230mm x 160mm (diameter x height)
Waterproof and dustproof
•
Detector
•
Tablet PC
IP65
IP655