68
2.5.3 Secondary coil
Attached with spark plug. Measure the impedance between
the wiring side of the spark plug cap and the terminals.
Standard: 5-11K
Ω
(
20
)
It shows good if the impedance is within the range of
standard values.
The impedance
∞
indicates that the coil breaks.
Remove the spark plug cap. Measure the impedance
between
the primary side wire of the ignition coil and the negative
terminal.
Standard: 0.5-5.5K
Ω
±10
%(
20
)
2.6 Trigger
* Note
Check the trigger on the engine.
Check
Remove the body guard.
Remove the trigger terminal.
Measure the impedance between the blue/white terminal of
the side wire of the engine and the body GND.
Standard: 100-500
Ω
(
20
)
Replace the magnetor if the measured value exceeds the
standard value.
(白:
white
蓝:
blue
绿:
green
)
(磁电机接口:
magnetor interface
黑:
black
绿
/
红:
green/red
白:
white
)
蓝/白
Ω
白/绿
磁电机接口
DJ621-2.8×0.5
DJ7031-2.8-21
白
黑
绿
/红
Ω