11
Fig. 4 Disinfectant filling port
3.5 Disinfectant Discharging
When you have to discharge the disinfectant in the robot, firstly, please pull out the gray
silicone plug on the top of the robot(DO NOT destroy the plug), as shown in Figure 5; then insert
the end of the hose of the pump into the head of the robot, and put the other end of the pump in the
container to catch the disinfectant; finally press the switch button on the top of the pump to start the
discharging. Please note: The robot can be turned on during this proceed. When the indicator light is
orange, it means that the disinfectant has been emptied. After the discharging is complete, please
put the silicone cover back on the top of the robot.
Attention: DO NOT spill disinfectant on any part of the robot!