HD IR Dome Camera
User Manual
32
4.3.6
Object Left
Enable this function in the interface to detect specific area at real time. When any object is left in the area, an
alarm will be triggered.
Go to
Settings > Event > Intelligent Function > Object Left
and configure. Setting steps can be referred to
in
Enter Guard Area.
4.3.7
Object Removal
Enable this function in the interface to detect specific area at real time. When any object is taken from the area,
an alarm will be triggered.
Go to
Settings > Event > Intelligent Function > Object Removal
and configure. Setting steps can be
referred to in
Enter Guard Area.
4.3.8
Gathering
Enable this function in the interface to detect specific area at real time. When moving objects exceed the
sensitivity, an alarm will be triggered. After setting the area and the sensitivity is set 50%, when 50% or more of
the area is covered by moving objects, an alarm will be triggered.
Go to
Settings > Event > Intelligent Function > Gathering
and configure. Setting steps can be referred to in
Enter Guard Area.
4.3.9
Audio Surge
After enabling this function, when there is audio surge, an alarm is triggered. The higher the Voice Intensity
Threshold is, the more sensitive it is to voice mutation.
Go to
Settings > Event > Intelligent Function > Audio Surge
.
Setting steps:
1) Check
“
Enable
”;
2) Drag the slide bar of
Voice Intensity Threshold
to adjust the detection sensitivity to voice mutation. The
higher the Voice Intensity Threshold is, the more sensitive it is to Voice Mutation;
3)
Duration
: user can set multiple durations and set different start time and end time for each duration.
Please refer to Step 4) in Motion Detection part;
4) Check
Linkage Type
and click
“
Save
”.
4.3.10
Alarm Input
Camera supports connecting with on-off alarm devices. If the alarm input device is always disabled, when it
alarms, the circuit will become a loop and the camera will trigger alarm output by the set alarm linkage type. If
the alarm input device is always enabled, when it alarms, the circuit will become open and the camera will
trigger alarm output by the set alarm linkage type.
Setting steps:
1) Confirm that the alarm input device is always enabled or always disabled and has been rightly connected
with the alarm input port of camera.
2) Go to
Settings > Event > Alarm Input
, and select a number from the dropdown list of Alarm Input ID
(corresponding to the connected input ID).
3) Enter alarm name. If the alarm input device is always disabled, which means the circuit is usually open,
user must select
“
Always Disabled
” from the dropdown list of Alarm Type. If the alarm input device is
always enabled, which means the circuit is usually loop, user must select
“
Always Enabled
” from the
dropdown list of Alarm Type. The default setting is
“Always Disabled”.
4) Duration: user can set multiple durations and set different start time and end time for each duration.
Please refer to Step 4) in Motion Detection part;
Summary of Contents for IPC427-D020-N
Page 1: ...KEDACOM User Manual for HD IR Dome Camera Version 03 July 2017 ...
Page 8: ...HD IR Dome Camera User Manual 4 2 Product Appearance Picture 2 1 IR Dome Camera ...
Page 13: ...HD IR Dome Camera User Manual 9 Picture 3 9 Web Client Interface ...
Page 46: ...HD IR Dome Camera User Manual 42 Picture 4 37 Restoration ...