Infrared Thermometer

   

Model

KC-180B-1 

Overview

 

KC-180B-1 handheld Infrared thermometer is a non-contact temperature measuring 

instrument using laser and infrared technology. You could use this product to measure the surface 

temperature of objects, which are not suitable for traditional contact measuring (such as moving 

objects, charged objects, toxic objects and hard-to-reach objects). 

The unit employs low consumption design and is capable to save the pre-set data 

automatically, avoiding resetting it after restart. The product features a LCD with backlight, 

holding the readings automatically and a laser pointer for accurate aiming. It has the advantages of 

rapid measuring, easy and safe operation and portability. It is widely used for applications as 

finding the hot spot of electric connections and bearings, measuring the temperature of high 

frequency induction heated objects, monitoring food processing and storage, inspecting 

temperatures of heat & refrigeration system, inspecting temperature for technics control in 

metallurgy industry, inspecting temperature during laying asphalt and fire-control process, or other 

circumstances in which the temperature field to be measured is not allowed to be compromised. It 

is an essential measuring instrument for the metallurgical industry, the electric power plants, the 

chemical industry, the rubber industry, the spinning and weaving industry, the plastic industry, the 

papermaking and the food processing. The product KC-180B-1 provides a type K-thermocouple 

input socket, which makes it possible to measure wider temperature range. 

KC-180B-1 Infrared thermometer is a Class II laser product and in compliance with the 

safety standard EN60825-1.

  

 

Safety Introductions 

Fail to follow the instructions listed below may cause personal injury. 

Read and understand all instructions prior to any operation. 

Do not remove any labels from the tool. 

Do not operate the tool in the presence of flammable/explosive gases. 

Do not operate the laser tool around children or allow children to operate the laser tool, failure to 

do so will injure children’s eyes. 

Do not stare into the laser beam. 

Do not project the laser beam directly into eyes of others. 

Do not set up the tool at eye level or operate the tool on or near a reflective surface, as the laser 

could be projected into people’s eyes. 

Summary of Contents for KC-180B-1

Page 1: ...Infrared Thermometer Model KC 180B 1 Operation Manual ...

Page 2: ...rature during laying asphalt and fire control process or other circumstances in which the temperature field to be measured is not allowed to be compromised It is an essential measuring instrument for the metallurgical industry the electric power plants the chemical industry the rubber industry the spinning and weaving industry the plastic industry the papermaking and the food processing The produc...

Page 3: ... laser radiation Battery Safety Instructions Please remove the batteries when clean the product Remove the batteries before long term storage Please install the batteries properly as the instructions of the positive and negative charges Please dispose the batteries properly High temperature will cause explosions and do not burn the batteries Strap insulated tape around the battery charges to avoid...

Page 4: ...missivity indicator I K thermocouple indicator J data log indicator K display logged data L display temperature max and min temperature set and emissivity M Celsius unit N Fahrenheit unit Operation Steps 1 Pull the trigger to turn on the meter and hold the trigger for measuring Be sure to hold the trigger more than 0 5 seconds to have an accurate reading The scan icon flashes while scanning After ...

Page 5: ...en the battery is low the low battery icon will appear on the upper area of the screen The and will appear on the upper of the display if the reading is lower or higher than the pre set low LAL and high HAL set 8 While inactive status press the right upper key to switch between infrared measuring and thermocouple measuring When appears then plug in the type K thermocouple into the socket which loc...

Page 6: ...c fields such as arc welding machine induction heaters C Static environment D Heat shock caused by abrupt temperature changes allow 30 minutes for unit to stabilize before use in such circumstance E Stay away from high temperature objects Trouble Shooting Problems Causes Possible Solution no display Dead battery Check and replace battery appears Low battery Replace battery OL appears The target te...

Page 7: ... and clean Don t place the tool with corrosive gas or objects Avoid dust and water which may stain the lens Don t clean the lens by any solvent Don t immerse the tool into water to avoid damage In case of damage of tool by deterioration of battery Remove the battery when not in use for an extended period of time Technical Specifications Name Infrared Thermometer Model KC 180B 1 Measuring range 50 ...

Page 8: ... o battery Product dimension L W H 135 mm 170 mm 36mm Weight w o battery About 168g w o battery Warranty The product is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase on the basis of providing relevant card Notice The warranty does not apply to the following conditions Disassembling the laser tool will void the warranty We are not ...

Reviews: