Configuration
52/68
5.2.1
Configuration examples
An example configuration for an OCPP connection via GMS could look as follows:
[/opt/KemoveCPM/etc/modules/hostconnector.properties]
chargeBoxIdentity=max-mustermann-P30
clockSynchMethod=OCPP
[CONFIGURATION]
AuthorizationEnabled=false
SetSecureConnection=false
CentralSystemAddress=http://keba.host.solutions:80/ocpp15
ChargepointAddress=localhost
ChargepointPort=12801
AmountConnectors=1
Connect2ConnectorSerial1=12345678
MaxAvailableCurrent=55000
NominalVoltage=230
PwmMinCurrentDefault=6000
predefinedTokenId=mustermann-P30
[NETWORK]
ConnectionType=GSM
LocalDHCPServerEnabled=true
GSM_APN=a1.net
[email protected]
GSM_APN_Password=ppp
GSM_SIM_PIN=1234
An example configuration for an OCPP connection via LAN could look as follows:
[/opt/KemoveCPM/etc/modules/hostconnector.properties]
chargeBoxIdentity=max-mustermann-P30
clockSynchMethod=OCPP
[CONFIGURATION]
AuthorizationEnabled=false
SetSecureConnection=false
CentralSystemAddress=http://keba.host.solutions:80/ocpp15
ChargepointAddress=localhost
ChargepointPort=12801
AmountConnectors=1
Connect2ConnectorSerial1=12345678
MaxAvailableCurrent=55000
NominalVoltage=230
PwmMinCurrentDefault=14000
predefinedTokenId=mustermann-P30
[NETWORK]
ConnectionType=LAN
LocalDHCPServerEnabled=false