ChargepointAddress=
IP address or char-
acter string
Example:
91.210.141.20
or
localhost
This parameter defines the IP address where the
OCPP central system can reach the charging sta-
tion.
Here, the URL from the charging station is merged
from this parameter and the parameter
Charge-
pointPort
.
●
If the OCPP central system is located on the
same network as the charging station, the local
IP address of the charging station is specified,
which is shown on the display, when the net-
work cable is plugged in. Make sure that this is
a static IP address in this case.
●
If the OCPP central system and the charging
station are not on the same network, a public
IP address must be specified where the charg-
ing station can be reached externally. On the
network router, a port forwarding from this pub-
lic IP address to the local IP address must be
set up.
●
If
localhost
is entered, the address will be de-
termined automatically. If a GSM connection is
used, the IP address of the SIM card will be dy-
namically determined and entered.
ChargepointPort=
1024 - 65535
This parameter defines the port where the charging
station can be reached.
AmountConnectors=
1 – 15
This parameter defines the number of the P20 resp.
P30 charging stations, which are to be connected to
the charging station (master).
Connect2ConnectorSerial1=
Connect2ConnectorSerial2=
Connect2ConnectorSerial3=
…
Serial number
Example:
15025563
This parameter defines the serial numbers of the
P20 / P30 (c-series slaves) in the network to which
the charging station (master) is to connect.
If this parameter value is left empty, it will automati-
cally be filled in with the serial numbers of the
charging stations (slaves) with which the charging
station (master) connects.
Note:
When replacing a connected charging station
(slave), the corresponding parameter value must be
deleted so that the replaced charging station can
connect again with the charging station (master).
MaxAvailableCurrent=
PWMMinCurrentDe-
fault –
527000
This parameter defines the connection load at the
charging environment (cluster) in mA.
NominalVoltage=
210 – 240
This parameter defines the nominal voltage of the
power supply network. This value is used for the
conversion into the charging power at the charging
environment.
PwmMinCurrentDefault=
≥
6000
This parameter defines the lower limit of the charg-
ing current (mA), which is still permitted before a
vehicle can be put into sleep mode by the load
management system.
predefinedTokenId=
Character string
Defines a predefined token (any character string) to
be sent to the OCPP host if no token is available.