47
General Control Card Parameters (Operator Functionality)
Id-Text
Name
Parameter index
os19
safety software version
0x2093
Meaning
Displays the software version of the safety module.
Type
Variable
Data length
32 bit
Access
read
Coding
0.0.0.0...255.255.255.255
If no safety module is installed, the value "0: no safety function-
ality“ is displayed.
Standard value: 0
Note
-
Id-Text
Name
Parameter index
os20
safety signals state
0x2094
Meaning
Displays the signal state of the safety module.
Type
Variable
Data length
8 bit
Access
read
Coding
Bit 0
no safety function-
ality
1: no safety functionality
Bit 1...2
Error STO
1: Error STO
2: STO OK
Bit3
ModFeedback
4: ModFeedback ist set
8: ModFeedback ist not set
Bit 4...5
ST Safety
16: ST is set
32: ST is not set
Bit 6...7
PU alive
64: PU alive
128: PU not alive
Standard value: 0
Note
-
Summary of Contents for COMBIVERT G6
Page 2: ...2...
Page 8: ...8 List of Tables List of Tables Table 1 assignment of the function keys 50...
Page 20: ...20...