42
General Control Card Parameters (Operator Functionality)
Id-Text
Name
Parameter index
os04
diag error count
0x2084
Meaning
Specifies the number of errors occurred on the diagnostic inter
-
face.
Type
Variable
Data length
8 bit
Access
read / write
Coding
0...255
Standard value: 0
Note
-
Id-Text
Name
Parameter index
os05
diag response delay time
0x2085
Meaning
Sets the minimum response delay time for requests on the diag-
nostic interface.
Type
Variable
Data length
8 bit
Access
read / write
Coding
0...126 ms
Standard value: 0 ms
Note
-
Id-Text
Name
Parameter index
os06
baud rate diag
0x2086
Meaning
Default transfer speed on the diagnostic interface.
Type
Variable
Data length
8 bit
Access
read / write
Coding
0: 1.2 kbit/s
1: 2.4 kbit/s
2: 4.8 kbit/s
3: 9.6 kbit/s
4: 19.2 kbit/s
5: 38.4 kbit/s
6: 55.5 kbit/s
7: 57.6 kbit/s
8: 100 kbit/s
Standard value: 5
Note
-
Summary of Contents for COMBIVERT G6
Page 2: ...2...
Page 8: ...8 List of Tables List of Tables Table 1 assignment of the function keys 50...
Page 20: ...20...