29
IO-Link Interface
3.4 Parameterization data (SPDU)
The device parameters can be addressed via a 16-bit index plus 8-bit sub-index. About
the subindex with the values 1...n each subindices or sets of parameters can be ad-
dressed.
About the subindex 0, all subindices 1...n addressed simultaneously. If at write access
a value can not be written (e.g. because it is outside the valid value range), all others
are still written. The first error message from several not possible write accesses is sent
to the master.
Generally written will be only the corresponding data type byte (incl. value range checks),
excess bytes are ignored. Exception when writing to subindex 0. In this case the num-
ber of bytes to be written are checked. When reading the correct data length is returned.
Summary of Contents for COMBIVERT G6
Page 2: ...2...
Page 8: ...8 List of Tables List of Tables Table 1 assignment of the function keys 50...
Page 20: ...20...