background image

simply loosen three dial plate retaining screws,
rotate dial plate to match thermometer reading and
tighten screws. For calibration over a 15°F
difference, contact your local service distributor.

NOTE: 

Locate thermometer in same position for every

calibration. Position next to upper heating element is
recommended.

C. Thermostat Bulb Positioning

Keating’s patented thermostat application is accurate
within ±2°F of the dial setting between 250°F and
350°F. This accuracy is attained only if the thermostat
bulb is placed properly next to the top element using

element clamps. If the bulb is too far away from the
element, the fryer will overshoot.

Overshoot

: The thermostat takes a long time to

cycle and then misses its preset temperature by
20°F - 40°F yielding a poor quality product.

D. Hi-Limit Check

The manual Hi-Limit test button can be used to test the
Hi-Limit Control by pushing and holding the button in
until the fryer reaches the Hi-Limit temperature
(425°F). Place an accurate thermometer in the oil. If
the Hi-Limit Control doesn’t shut off the fryer between
425°F and 450°F, have it replaced.

10

V SERVICE DIAGNOSIS

A properly adjusted Keating Instant Recovery® Electric Fryer, with no load, will cycle “on” approximately every 2-
1/2 to 3 minutes. Each cycle will last 15-25 seconds, ensuring that the temperature setting is held within a
narrow band.

Every Keating Instant Recovery® Electric Fryer has a number of safety controls to ensure safe operation and
guard against component failure. 

A. Trouble shooting

The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that
you use a qualified service company. Call 1-800-KEATING if you need assistance in locating a qualified service
company.

PROBLEM

PROBABLE CAUSE

SOLUTION

Fryer won’t heat

a. No electricity to fryer (“POWER

a. Connect fryer to an approved source of  

ON” light is off).

power.

b. No electricity to control circuit

b. Connect 120V terminal block to an 

(models with Basket-Lift or Central

approved source of power.

Filter).

c. Fryer circuit breakers have tripped. c. Reset circuit breakers.

d. Hi-Limit has been activated.

d. Push in Hi-Limit reset button located 

behind fryer door. Check calibration of 
thermostat and operation of Hi-Limit and 
contractor.

e. Rear drain valve handle has

e. Fully close and latch rear drain valve 

not been fully closed (fryers

handle.

with filter only).

f. Control circuit fuse is blown.

f.

Replace fuse. (Use type SC-5 for 10x11 
and 14TS BL models and type SC-3 for 
all other models.)

g. On/Off/Melt Switch is faulty.

g. Replace On/Off/Melt Switch.

h. Contactor is faulty.

h. Replace contactor.

i. Thermostat is faulty.

i.

Push and hold in Hi-Limit test button. If 
elements turn on, thermostat is faulty. 
Replace thermostat.

Summary of Contents for INSTANT RECOVERY GAS FRYER

Page 1: ...INSTANT RECOVERY ELECTRIC FRYER SERVICE MANUAL KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1 800 KEATING www keatingofchicago com elecFryPre2000_0310 03 13 part 000784...

Page 2: ...7 18 34 x24 Basket Lift Control Panel 18 14 Basket Lift Housing and Roller Guide Parts List 19 18 34 x24 Basket Lift Housing Roller Guide and Transformer Box Parts List 20 SECTION VII WIRING DIAGRAMS...

Page 3: ...come with all the same features as the TS Model The Basket Lift mechanism lowers the baskets of food into the oil when the timer button is pressed and raises the baskets when the cooking cycle is comp...

Page 4: ...the shipping container for inspection Keating does not assume responsibility for Loss OR Damage incurred in transit INSTALLATION Installation must conform with local codes or in absence of local code...

Page 5: ...If your fryer is to be fed by a 208 or 220 volt system consult the Keating Fryer Specifications on pages 37 and 38 to determine the full load rating of the fryer NOTE Some fryers with Basket Lifts Zer...

Page 6: ...el and a true COLD ZONE mean extended oil life Follow cooking procedures below for your model WARNING OPERATION OF THIS FRYER SHOULD BE LIMITED TO PERSONNEL WHO HAVE BEEN THOROUGHLY TRAINED IN OPERATI...

Page 7: ...ly lower into fryer vessel 8 When cooking cycle is complete an audible alarm will sound and the basket s will raise automatically Allow oil to drain before removing baskets D CPU Model See separate co...

Page 8: ...age 5 Draining 2 Turn the fryer off 3 Drain oil from fryer see page 5 Filtering may be done at this step 4 Remove oil container to a secure area to prevent accidental spillage 5 Fill fryer vessel to F...

Page 9: ...yer with new or filtered oil ELECTRONIC CONTROL TIMERS The electronic timers provide a clearly visible and accurate display and are very easy to use 10X11 14 TS MODELS A Keating Electronic Timer B How...

Page 10: ...in upper position 10 08 2 Clock mode display will show a decimal point in lower position 10 08 OPTIONAL TIMER OPERATING INSTRUCTIONS PART 056921 DIGITAL TIMERS The electronic timers standard on TS mod...

Page 11: ...ognized as being the best metal for use in the construction of fryer vessels That is why all Keating fryer vessels and heating elements are made of stainless steel that is highly polished to a 7 mirro...

Page 12: ...last 15 25 seconds ensuring that the temperature setting is held within a narrow band Every Keating Instant Recovery Electric Fryer has a number of safety controls to ensure safe operation and guard a...

Page 13: ...replace if necessary c Dirty fryer vessel c Boil out fryer See page 10 Cleaning and Boil out d Inferior grade of oil d Check with oil supplier for higher grade of oil needed fir your cooking applicat...

Page 14: ...goes a Basket Lift motor limit switch is a Align limit switch down but won t go up misaligned 10x11 and 15 TS BL models Basket Lift buzzer won t a Buzzer limit switch is misaligned a Align limit switc...

Page 15: ...4 4 5 TERMINAL BLOCK 208 480V 034381 1 1 1 1 1 6 TERMINAL BLOCK 002565 3 1 7 CIRCUIT BREAKER 208 240V 1P 40A 012129 CALL 1 800 KEATING 2P 40A 015203 CALL 1 800 KEATING 3P 40A 015204 CALL 1 800 KEATIN...

Page 16: ...14 ELECTRIC FRYER ASSEMBLY I NOTE Part numbers correspond with the Electric Fryer Parts List on page 13 ELECTRIC FRYER ASSEMBLY II Exploded view of heating element wire connection hardware...

Page 17: ...0 5 ON OFF MELT SWITCH PLATE 1 009919 6 TOGGLE SWITCH ON OFF MELT 1 004326 7 INDICATING LIGHT AMBER 220V 2 004157 8 HI LIMIT TEST PLATE 1 004305 9 HI LIMIT TEST BUTTON 1 004304 10 POWER ON LIGHT PLATE...

Page 18: ...AT KNOB BLACK 1 060612 4 RETAINING SCREWS 3 004610 5 LIGHTS WHITE 3 016639 LIGHT RED 1 016640 MOUNTING PLATE 1 6 TOGGLE SWITCH ON OFF MELT 1 004326 7 HI LIMIT TEST BUTTON 1 004304 8 TIMER 2 023709 9 M...

Page 19: ...T KNOB BLACK 1 060612 4 RETAINING SCREWS 3 004610 5 SET OF 4 LIGHTS 120V WITH PLATES 1 004156 6 TOGGLE SWITCH ON OFF MELT 1 004326 7 HI LIMIT TEST BUTTON 1 004304 8 TIMER 2 023709 9 MELT CONTROL 120V...

Page 20: ...NG SCREWS 3 004610 5 SET OF 4 LIGHTS 120V WITH PLATES 1 004156 6 TOGGLE SWITCH ON OFF MELT 1 004326 7 HI LIMIT TEST BUTTON 1 004304 8 TIMER ELECTRONIC 2 023709 9 MELT CONTROL 120V 1 004169 10 NUT WITH...

Page 21: ...CCW LEFT Viewing front of fryer 1 000390 9 MOTOR CW RIGHT Viewing front of fryer 1 000391 10 BUZZER ON OFF SWITCH WITH PLATE 1 004499 11 BUZZER 1 004223 12 FUSE HOLDER 2 SEE PAGE 13 13 FUSE GROUND FA...

Page 22: ...LIFT ROD FOR SPLIT BASKETS 2 020086 6 BUSHING PUSH ROD 4 016405 7 BUSHING RETAINING RING 4 015831 8 FUSE HOLDER 2 004335 9 FUSE ACTUATOR GROUND FAULT 3A SC 3 2 004334 10 TRANSFORMER STEPDOWN 120V 24V...

Page 23: ...d should be saved for troubleshooting and maintaining the fryer The wiring diagrams in this section cover standard fryers which may or may not match the diagram sent with the fryer Non standard fryers...

Page 24: ...22 14 TS AND 14 TS WITH WHIRL O SWIRL A WAY WIRING DIAGRAMS 14 TS WITH WHIRL O SWIRL A WAY 14 TS...

Page 25: ...23 14 20 TS 18 20 TS WITH WHIRL O SWIRL A WAY WIRING DIAGRAMS 18 20 TS 18 20 TS WITH WHIRL O SWIRL A WAY...

Page 26: ...24 14 TS WITH BASKET LIFT WITH WHIRL O SWIRL A WAY WIRING DIAGRAMS 14 TS WITH BASKET LIFT 14 TS WITH BASKET LIFT WITH WHIRL O SWIRL A WAY...

Page 27: ...25 24 TS WITH BASKET LIFT WITH WHIRL O SWIRL A WAY WIRING DIAGRAMS 24 TS WITH BASKET LIFT 24 TS WITH BASKET LIFT...

Page 28: ...SE 208 21 5 68 68 45 103 220 24 0 72 72 47 109 240 28 6 79 79 52 119 AMPS PER LINE THREE PHASE 4 ELEMENTS 6000 W EACH 24 BB FM E A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 16 1 45 45 45 77 220 18 0 47...

Page 29: ...68 129 220 30 0 72 95 72 136 240 35 7 79 103 79 149 AMPS PER LINE THREE PHASE 5 ELEMENTS 6000 W EACH 24 TS FM E A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 21 5 68 68 45 103 220 24 0 72 72 47 109 240...

Page 30: ......

Page 31: ..._______________________ ADDRESS ______________________________________________________________________________________________________________ CITY ____________________________________________________...

Reviews: