17
Operation and Service megaSun 7900
5.3 Filter
panes
Safety function
The facial tanners are equipped with an additional safety
function. Behind each of the
fi
lter panes there is a safety switch
that switches off the burner if a pane is missing or broken.
Do not operate the tanning system with a defective fi lter pane.
Carry out regular visual inspections!
Filter panes have to be replaced only by those of the same type!
The fi lter panes may be dismantled and replaced by trained
expert staff only.
Filter panes in the
canopy
The following table shows how to dismantle the frame of the
fi
lter panes.
Illustr. 5-8 Dismantling the
tube cover
Illustr. 5-9 Dismantling the
fi
lter pane frame
Filter panes in the
lateral part
This frame is to be dismantled as follows:
Step
Procedure
Reference
1
Dismantle the acrylic pane.
Section 3.2
2
Undo the screws of the tube cover in the facial area to
remove the tube cover.
3
Undo the screw of the lower
fi
lter pane frame. Hold the
frame. Tilt it down and then take it out.
4
Also hold the front frame when undoing the screws.
Now you can take it out as well.
Step
Procedure
Reference
1
Completely dismantle the acrylic pane.
Section 3.2
2
Undo the screws of the tube cover in the facial area to
remove the tube cover.
Section 3.3.
3
Lift the frame and swing it forward.
Section 3.3.
4
Lift the base pane
Section 3.2