Operation and Service megaSun 7900
5.
Maintenance of the apparatus
Preparatory works
Before you open the apparatus, switch off the fuses to discon-
nect it from the mains supply!
Do not operate the tanning unit without the front panels, without
acrylic panes or with the base section opened, because other-
wise the tanner areas will overheat. This will destroy the fi lter
panes!
As far as CPI-equipped units are concerned, the electronic
switchboxes located under the bed are also exposed to the dan-
ger of overheating.
5.1
Cleaning and care
Plastic parts
Note
The bigger plastic parts are made of solid, high-quality ABS
material. On top of it you will
fi
nd a hardwearing, transparent
PMMA-layer.
The surfaces and the acrylic glass must not be cleaned with
concentrated disinfectants or solvents or other liquids that
contain alcohol!
The manufacturer cannot be held liable for any damages caused
by chemically active agents such as inappropriate cleaning
agents.
To clean the varnished and plastic surfaces use a damp soapy
cloth.
It must be avoidted at any rate that cleaning fl uid runs into the
apparatus.
Acrylic panes
For a harmless cleaning of the acrylic panes use the special
cleaning and disinfectant
fl
uid „ megaClean “ (to be obtained
from KBL) which has to be diluted in water at a ratio of 1:13
Fixing the canopy
The canopy can be
fi
xed in the upper position, to perform
service and maintenance works.
To do so, open the canopy and move the bolt at the right back
to the front. If you push the bolt to the back the canopy will be
released.
After removing the screws on the left and on the right, the bed
pane can be fastened to the canopy. For that purpose, use the
hook and hang it into the opening in the centre between the
fi
lter
mats.