installation manual

 

1

 

 

CONTENTS 

 

 

 

 

PAGE

 

Disassembling, replacement and maintenance of 

filter should be carried out by qualified person.

 

 

If the supply cord is damaged, it must be replaced by the 

manufacturer or its service agent or a similarly qualified person 

to avoid a hazard.

 

 

An all-pole disconnection switch having a contact separation of 

at least 3mm in all poles should be connected in fixed wiring.

 

 

The appliance shall be installed in accordance with national 

wiring regulations.

 

 

The temperature of refrigerant circuit will be high, please keep 

the interconnection cable away from the copper tube.

 

 

An all-pole disconnection device which has at least 3mm 

separation distance in all pole and a residual current device 

(RCD) with the rating of above 10mA shall be incorporated in the 

fixed wiring according to the national rule.

 

The power cord type designation is H05RN-R/H07RN-F or above.

 

 

 

 

 

2.  INSTALLATION PLACE

 

 

 

1.

 

INSTALLATION PRECAUTION

 

To install properly, please read this manual at first.

 

 

The air conditioner must be installed by qualified persons.

 

 

When installing the indoor unit or its tubing, please follow this 
manual as strictly as possible.

 

 

When all the installation work is finished, please turn on the power 
only after a thorough check.

 

 

No further announcement if there is any change of this manual 
caused by product improvement.

 

 

 

 

The installer should illustrate  to  users how  to correctly  use  and 
maintain the air-conditioner, as well as remind users to carefully 
read  and  keep  both  Installation  Manual  and  Owner's  Manual 
well.

 

DISPOSAL:

 

Do not dispose this product as unsorted municipal 

waste. Collection of such waste separately for special treatment 
is necessary.

 

 

This appliance is not intended for use by persons (including 
children) with reduced physical, sensory or mental capabilities, 
or lack of experience and knowledge, unless they have been 
given supervision or instruction concerning use of the appliance 
by a person responsible for their safety.

 

Children should be supervised to ensure that they do not play 
with the appliance.

 

Disconnect the power supply before cleaning and maintenance. 

The appliance must be installed 2,3m above floor.

 

The appliance shall not be installed in the laundry.

 

 

The appliance shall be installed keep away from quiet place, 

such as bedroom.

 

Indoor Unit

 

 

● 

Enough room for installation and maintenance.

 

● 

The ceiling is horizontal and it can afford the weight of the indoor 
unit.

 

 

● 

The air inlet and outlet are not impeded and does not affected by 
outdoor air too much.

 

 

● 

The air flow can reach every part of the room.

 

 

● 

The connecting pipe and drainpipe can be easily extracted out.

 

 

● 

There is no direct radiation from heat source.

 

Outdoor Unit

 

● 

Enough room for installation and maintenance.

 

● 

The air inlet and outlet are not impeded and does not affected by 
outdoor air too much.

 

 

● 

Dry and well-ventilated place.

 

 

● 

The supporter is flat and horizontal and can afford the weight of 
outdoor unit, without noise and vibration.

 

 

● 

The noise and the outlet air will not influence your neighbor.

 

 

● 

No combustible gas.

 

 

● 

Place convenient for piping and wiring.

 

 

Please keep away from the following places, or malfunction may 
be caused.(if unavoidable, please consult the professionals):

 

 

There is mineral oil like the oil of cutting machine.

 

 

● 

There is much salty air. (Near the coast)

 

 

● 

There is caustic gas such as sulfuric gas. (Near the hot spring.)

 

 

● 

Factory where the voltage fluctuate greatly.

 

 

● 

In the car or in the cabin.

 

 

● 

In the kitchen or a place full of oil steam.

 

 

● 

There is strong electromagnetic wave.

 

  

NOTE 

 

 

INSTALLATION  PRECAUTION ............................................................... 1

 

INSTALLATION  PLACE. ........................................................................ 1

 

 

INDOOR UNIT INSTALLATION ................................................................2

 

INSTALLATION  SPACE ........................................................................ 10

 

REFRIGERANT PIPE .............................................................................. 10

 

DUCT  DESIGN ...................................................................................... 11

 

INSTALL  THE  CONNECTING PIPE ..................................................... 17

 

REFRIGERANT  PIPE  CONNECTION ................................................... 18

 

CONNECT  THE  DRAIN PIPE ............................................................... 19

 
 

CONTROL ............................................................................................. 21

 

TROUBLE SHOOTING. ......................................................................... 24

 

INSTALL ELECTRICTHROTTLE PART ................................................. 25

 

INSTALL BRANCH PIPE. ..................................................................... 25

 

TEST OPERATION. .............................................................................. 25

 

Summary of Contents for KPDHF-71 DN3.0

Page 1: ...0 DN3 0 KPDHF 160 DN3 0 KPDHF 200 DN3 0 KPDHF 250 DN3 0 KPDHF 280 DN3 0 The Digital Scroll and DC AC Inverter share the same indoor units Thank you very much for purchasing our air conditioner Before...

Page 2: ...MD14I 041FW DZ2 16100101A01132...

Page 3: ...nce and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do n...

Page 4: ...ive and negative poles are in right positions when loading batteries 4 INDOOR UNIT INSTALLATION Installing 10 Hanging Screw Bolts 4 Bolts Please refer to the following figure for the distance measurem...

Page 5: ...eel refer to Fig 4 4 Overhanging the indoor unit Fig 4 4 Fig 4 7 Overhang the indoor unit onto the hanging screw bolts with block Position the indoor unit in a flat level by using the level indicator...

Page 6: ...ONNECTION SAFETY DRAIN CONNECTING PIPE AIR OUTLET 255 33 65 722 65 Fig 4 9 14 16KW 135 930 88 Unit mm PLASTIC COVER 68 24 46 ELECTRICAL CONTROL BOX 4 12 25OBLONGSUSPENTIONBOLTHOLES AIR INTAKE CONNECTI...

Page 7: ...w as Fig 4 11 SafetyDrainTray Fig 4 12 2 Remove the all 11 screw from fixed Safety Drain Tray and then take off the tray as figure showed in Fig 5 11 3 Take off the tray along the direction of the arr...

Page 8: ...all 4 bolts from reinforced panel and take off the panel 3 Refer to Fig 4 13 remove all 4 bolts from fan assembly see Fig 4 14 according to which orders to take off the fanassembly 4 Refer to Fig 4 1...

Page 9: ...11 screw from fixed Safety Drain Tray and then take off the tray as figure showed inFig 4 16 3 Take off the tray along the direction of the arrow show in Fig 4 16 4 Clean the tray and evaporator 5 Re...

Page 10: ...m fan assembly see Fig 4 18 according to which orders to take off the fan assembly 3 Refer to Fig 4 18 horizontal pushing the fan assembly until it cannot not move any further and then lift up slightl...

Page 11: ...nnection 9 52 3 8 Refrigerant pipe flared connection 16 5 8 Air intake duct flange 1270 Connecting point of drain pipe 43 125 100 Air intake 936 200 Fig 4 19 The method of installation adopt following...

Page 12: ...onfirm that there is enough room for installation and mainte nance Maintenance roomage Maintenance roomage motor assembly bottom cover plate screw Confirm the minimum drain tilt is 1 100 or more check...

Page 13: ...ut dust filter dust adherent on the air heat exchanger may cause failure and water leak Key points of duct connection Canvas tie in Canvas tie in Fig 7 1 Other assemblies should be prepared on spot ex...

Page 14: ...12 9KW model fan curve the static pressure refer to Table 12 2 Low fan speed High fan speed Fig 7 7 Fig 7 5 11 2KW model fan curve the static pressure refer to Table 12 2 Middle fan speed Fig 7 6 Hig...

Page 15: ...installation manual 13 Middle fan speed 14KW model fan curve the static pressure refer to Table 12 2 High fan speed Low fan speed Fig 7 9 Fig 7 10 Middle fan speed Fig 7 11 Fig 7 12...

Page 16: ...installation manual 14 Low fan speed Middle fan speed Fig 7 13 16KW model fan curve the static pressure refer to Table 12 2 Low fan speed Fig 7 15 High fan speed Fig 7 16 Fig 7 14...

Page 17: ...20KW model fan curve the static pressure refer to Table 12 2 Low fan speed High fan speed Fig 7 19 Middle fan speed Fig 7 17 25KW 28KW model fan curve the static pressure refer to Table 12 2 High fan...

Page 18: ...1 Hang the outside frame on the main body with face down 4 places at 4 corners Hang the belt on the hook of the main body Low fan speed Fig 7 22 The signal wire of the remote control receiver must be...

Page 19: ...urities may enter the pipe system and may cause malfunction later So please expel the air out of the pipe with refrigerant before connection Expel the air refer to the Expel The Air after connectingth...

Page 20: ...pipe cutter Insert a flare nut into a pipe and flare the pipe lean crude burr 9 2 Check The Leakage Fig 9 1 Fasten the nut Put the connecting tubing at the proper position wrench the nuts with hands...

Page 21: ...l should be more than 50mm and the drain pipe cannot put in water If the drain water was discharged to ditch directly the drain pipe must be upward bent into a U type water seal to avoid odor into the...

Page 22: ...itioners The wiring of 71T1 to 160T1 indoor unit please refer to Fig 11 3 and Fig 11 4 is the wiring for 200T1 250T1 and 280T1 indoor unit Table 11 1 Capacity KW 71 80 90 112 140 160 200 250 280 Power...

Page 23: ...DOOR COMM BUS POWER INPUT Y G For 200 250 280 models TA A T1 A T2 A T2B A XP4 XS4 XP5 XS5 OLD DISPLAY BOARD WIRE CONTROLLER DC FAN TA B T1 B T2 B T2B B WHITE BLACK CN23 CN24 CN25 CN26 CN15 CN10 CN16 W...

Page 24: ...ll distribute different addresses for indoor units automatically When V4 outdoor unit set the code to be found address non automatically all the indoor units must set the system addresses by remote co...

Page 25: ...ing SW6 ON 1234 l reserved For B SYSTEM SW 1 Difinition SW 2 Difinition SW3 ON 1 2 l 00 means the time ofstopping TERMAL fan is 4 mintues SW3 ON 1 2 l 01 means the time ofstopping TERMAL fan is 8 mint...

Page 26: ...rtfunction J2 l r eserve d 0 1 Definition ON l means 0 ON l means 1 Please adjust the code ENC1 to the suitable position both system A and B should be adjusted for 200T1 250T1 and 280T1 indoor unit Th...

Page 27: ...rement install the remotecontroller frame where the remote controller s signal can reach the indoor unit smoothly Test operation Set the air conditioner under the mode of COOLING with the remotecontro...