16
Maintenance
Maintenance tips
- Be sure to clean the air filter every 2 weeks for opti-
mal perfomance.
- The water collection tray should be drained imme-
diately after P1 error occurs, and before storage to
prevent mold.
- In households with animals, you will have to periodi-
cally wipe down the grill to prevent blocked airflow fue
to animal hair.
Clean the Unit
Clean the unit using a damp, lint-free cloth and mild
detergent. Dry the unit with a dry, lint-free cloth.
Storafe the unit when not in use
- Drain the unit’s water collection tray according to the
instructions in the following section.
- Run the appliance on FAN mode for 12 hours in a
warm room to dry it and prevent mold.
- Turn off the appliance and unplug it.
- Clean the air filter according to the instructions in the
previous section. Reinstall the clean, dry filter before
storing.
- Remove the batteries from the remote control.
Be sure to store the unit in a cool, drak place. Exposu-
re to direct sunshine or extreme heat can shorten the
lifespan of the unit.
NOTE: The cabinet and front may be dusted with an
oil-free cloth or washed with a cloth dampened in a so-
lution of warm water and mildliquid dishwashing deter-
gent. Rinse thoroughly and wipe dry. Never use harsh
cleansers, wax or polish on the cabinet front. Be sure to
wring excess water from the cloth before wiping around
the controls. Excess water in or around the controls
may cause damage to the unit.
Faults Diagnosis
Please check the machine according to the following form before asking for maintenance:
Problem
Possible Cause
Troubleshooting
Unit does not turn on
when pressing ON/
OFF button
P1 Error Code
The Water Collection Tray is full. Turn off the unit,
drain the water from the Water Collection Tray and
restart the unit.
In COOL mode: room temperature is
lower than the set temperature
Reset the temperature.
Unit does not cool
well
The air filter is blocked with dust or
animal hair
Turn off the unit and clean the filter according to
instructions
Exhaust hose is not connected or is
blocked
Turn off the unit, disconnect the hose, check for bloc-
kage and reconnect the hose
The unit is low on refrigerant
Call a service technician to inspect the unit and top off
refrigerant
Temperature setting is too high
Decrease the set temperature
The windows and doors in the room are
open
Make sure all windows and doors are closed
The room area is too large
Double-check the cooling area
There are heat sources inside the room
Remove the heat sources if possible
The unit is noisy and
vibrated too much
The ground is not level
Place the unit on a flat, level surface
The air filter is blocked with dust or
animal hair
Turn off the unit and clean the filter according to
instructions
The unit makes a
gurgling sound
This sound is caused by the flow of
refrigerant inside the unit
This is normal
Summary of Contents for KP-35 CP10