Installation & Owner‘s Manual
9
2.1 Function instructions
2.2 Operation conditions
2.3
Key words
1. For the new series product, we can connect the indoor CCM controller via XYE port of master
outdoor unit of every refrigerant system. Notice that in this case, the outdoor unit must be set to
automatic serching address mode. And it will be effective after about 6 minutes.
2. To connect indoor CCM controller via XYE port of indoor unit, this wiring method is suitable for
all type of indoor units, not just for new indoor units.
3. When new indoor units and old indoor units mix connect to one refrigerant system, we can only
use centralized controller to control old generation IDUs via their own XYE port or control the
new geration IDUs via master ODU's XYE port. We can't control all of them.
4. If one system that connect to indoor CCM controller include 10 HP or above duct indoor unit,we
recommend you set the address of every indoor unit manually.
1. Power and voltage range:
Input voltage: single phase 198V~242V;
AC input power frequency: 50Hz/60Hz;
2. Operating environment temperature: -15
℃
~+43
℃
;
3. Operating environment humidity: RH40%~RH90%.
2.3.1 State indication
1. LED for state indication
1) Normal state
①
On
The LED will be on when any one of the following occur:
a) In thhe centralized controller network, one or more air conditioners are under operating
state.
b) Through the centralized controller’s operation, when the centralized controller is
sending order to the air conditioners,the LED will be on. When centralized controller
finishes sending,the LED will be off.
②
Off
The air conditioners in the centralized controller network are all under off status.
2) Abnormal state
If the air conditioners in the centralized controller network are error or the controller
network is error, the LED will flash as 2 Hz.