Installation & Owner's Manual
2
Display
Air
outlet
Barrier
≥
600
650
≥
600
≥
600
Air
inlet
Φ650
≥
600
≥
800
≥
600
650
1920
● This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised
to ensure that they do not play with the appliance.
● If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified person.
● DISPOSAL: Do not dispose this product as
unsorted municipal waste. Collection of such
waste separately for special treatment is
necessary.
Do not dispose of electrical appliances as
unsorted municipal waste, use separate collection
facilities. Contact your local government for
information regarding the collection systems
available.
If electrical appliances are disposed of in landfills or dumps,
hazardous substances can leak into the groundwater and get into
the food chain, damaging your health and well-being.
CAUTION
● The earthing pole of socket must be grounded well, make
sure that power supply socket and plug are dry enough and
connected tightly.
● How to check the power supply socket and plug are qualified?
Turn on power supply and keep the unit running for a half hour,
then turn off power supply and plug out, check whether the
socket and plug is hot or not.
● Before cleaning, be sure to stop the operation and turn the
breaker off or pull out the power plug.
Otherwise, an electric shock and injury may be caused.
● Water temperature over 50
℃
can
cause severe burns instantly or
scalds. Children, disabled and
elderly are at highest risk of being
scalded. Feel water before bathing
or showering. Water temperature
limiting valves are recommanded.
● Do not operate the unit with a wet hand.
An electric shock may be caused.
● The installation height of power supply should be over 1.8m, if
there is any water spattered, separate the power supply from
water.
● A one-way valve must be installed on the water inlet side,
which is available from accessories, see manual "accessories"
part.
● It’s normal if some water drops from the hole of PTR valve
during operation. But, if there is a great amount of water, call
your service agent for instructions.
● After a long term use, check the unit base and fittings.
If damaged, the unit may sink and result in injury.
● Arrange the drain pipe to ensure smooth draining.
Improper drainage work may cause wetting of the building,
furniture etc.
● Do not touch the inner parts of the controller.
Do not remove the front panel. Some parts inside are
dangerous to touch, otherwise a machine malfunction may be
caused.
● Do not turn off the power supply.
System will stop or restart heating automatically. A continuous
power supply for water heating is necessary, except service and
maintenance.
● If the unit has not been used for a long period of time(2 weeks or
more), hydrogen gas will be produced in the water piping system.
Hydrogen gas is extremely flammable. To reduce the risk of injury
under these conditions, it is recommended that open the hot
water tap for several minutes at the kitchen sink before using any
electrical appliance connected to the hot water system. When
hydrogen is present, there will probably be an unusual sound
such as air escaping through the pipe as the water begins to flow.
There should be no smoking or open flame near the tap at the
time it is open.
2. BEFORE INSTALLATION
2.1 Unpacking
2.1.1 Accessories
Table.2-1
Accessory Name
Qty.
Shape
Purpose
Owner’s &
Installation Manual
1
Installation and use
instruction This manual
One Way Valve
1
Prevent water from flowing
backwards
Adaptor
1
Drain condensate water
2.1.2 How to transport
1) In order to avoid scratch or deformation
of the unit surface, apply guard boards to
the contacting surface.
No contact of fingers and other things with
the vanes.
Don’t incline the unit more than 15°
in moving, and keep it vertical when
installing.
2) This unit is heavy, it need to be carried by two or more persons,
othewise might cause injury and damage.
2.2 Location requirements
1) Enough space for installation and maintenance shall be
preserved.
2) The air inlet and outlet should be free from obstacles and strong
wind.
3) The base surface should be flat, surface should be inclined no
more than 2° and able to bear the weight of the unit and suitable
for installing the unit without increasing noise or vibration.
4) The operation noise and air flow expelled shall not affect
neighbors.
5) No flammable gas is leaked nearby.
6) It is convenient for piping and wiring.
7) If it is installed in indoor space, it might cause indoor temperature
decreased and noise. Please take preventive measures for this.
8) If the unit has to be installed on a metal part of building, make
sure the well electric insulation which should meet the relevant
local electric standard.
Gradient limit>75°
>75°