5. Adjustment & “Calibration”
The CLASSIC 800 is a digital flow, lev
el, interface and temperature switch/transmitter and is built to require
minimal maintenance and no calibration beyond proper installation and setup.
•
The Kayden Electronics Modules are completely digital and hav
e no mov
ing parts or mechanical
trim pots that could be effected by v
ibration or high unit cycles.
•
True temperature compensation is programmed into the firmware and is continuously factored into
the operation algorithms of the microprocessor.
•
The heater is a separate element from the sensors and is itself directly controlled by the
microprocessor.
Therefore, once properly setup, the CLASSIC 800 will be as stable and repeatable as the process in which
it is installed. For instance should the application change from Flow to Lev
el or the media change from
Hydrocarbon to Water-based or the Flow Rate increase or decrease significantly it may be necessary to
check and/or change the setup parameters (Range, Heater Power, Set Point).
6. Using the Kayden RCM Software to Satisfy Preventative Maintenance Requirements
One feature of the Kayden RCM Software* is the Configuration function which automatically stores all setup
information and displays it on the Configuration screen within the software whenev
er the CLASSIC 800 is
connected to a PC. This information may be named, stored and emailed as a file to preserv
e all operation
setup parameters.
Therefore, the user may construct “Maintenance Only Setup Parameters” with a slightly different heater
setting and set point and sav
e these as a file. This Maintenance Setup File could then be loaded in place of
the normal operating setup which will cause the display and relay function to change accordingly. Once this
change is observ
ed the normal setup can be reloaded and the prev
entativ
e maintenance requirement
satisfied.
*The Kayden RCM Software is av
ailable upon request, at no charge on CD, when a new CLASSIC 800
is purchased. Additional copies may be obtained at no charge from kayden.com or your local Kayden
representativ
e. In addition to the software you will need the SCA Serial Communication Adapter, the
USB to Serial conv
erter and communication cable. These can be ordered from your local Kayden
representativ
e.
25472-1 01 -V1 A-JF00-W0010 Rev 02
Summary of Contents for CLASSIC 800 Series
Page 2: ...25472 101 V1A JF00 W0010 Rev 02...
Page 3: ...25472 101 V1A JF00 W0010 Rev 02...
Page 73: ...kayden com 65 CLASSIC 800 CLASSIC 800 Product Manual Notes 25472 101 V1A JF00 W0010 Rev 02...
Page 74: ...kayden com 66 CLASSIC 800 CLASSIC 800 Product Manual Notes 25472 101 V1A JF00 W0010 Rev 02...