SYSTEM
LIMITATIONS
Kattsafe recommends that persons using fall arrest
systems do not work alone in case of an emergency
and help is required.
Should any part of the system/equipment have
been subjected to abnormal loading, use must
be discontinued until replaced/recertified by a
competent height safety inspector.
1. Minimum structural requirements for attachment of
guardrail:
– Metal roof deck – 0.42mm base metal thickness
– Timber floor - 16mm MDF or composite
– Concrete - 75mm slab (25 Mpa)
2. Guardrails are not designed for public access where
crowd loadings are required.
3. The maximum height of the handrail cannot exceed
1100mm after which additional handrail bracing and
support structure will be required.
4. Guardrail must not be installed on a roof pitch in excess
of 350 as the system is not designed to withstand a
dynamic fall load.
5. Guardrail is not designed to support rope access / abseil
systems which will need to be configured independently
of the guardrail system.
6. This system, under normal use and environment, has
a life expectancy of up to 10 years. A manufacturer’s
assessment and certification to confirm suitability for an
additional 5 years use is recommended. This will depend
on location, usage and scheduled maintenance as per
manufacturer and legislative requirements.
7. Do not tamper with or make alterations to system
components without manufacturer’s consent.
8. This system is not to be used for tethering or lifting
machinery or equipment.
9. The safety system must be recertified by a competent
height safety inspector as recommended:
– Non corrosive/mild environment – 12 monthly
– Corrosive/harsh environment – 6 monthly (more frequent
inspection may be required)