51 / 123
Open the valve by pulling the pneumatic
control button (5).
Close the valve by pressing the pneu-
matic control button.
In some cases, the butterfly valve that
used as a safety valve may not be pneu-
matically
controlled,
but
manually
controlled.
The ability to control the pneu-
matic actuator with a remote
control system can be added
to the vehicle upon customer
request.
Discharge pneumatic control box
4.1.13. Remote Control System
It is the system that allows the control of
the top air line, bottom valve and safety
valve to be done with the remote control
or the panel on the vehicle.
Remote control
Turning on the remote control:
•
Rotate the emergency button (1) on
the right side of the panel to open
position.
•
Rotate the power button (2) on the
right side of the panel to open
position.
Control panel
•
Rotate the button on the left end (3)
of the panel to left to activate the
control by remote.
Control panel
•
Rotate the emergency button (4).
Thus, the remote control switches
from ‘off’ to ‘on’ and resumes stand-
by status.
•
LED light (5) on the upper centre on
the control lights up continuously in
green at standby.
•
Two LED lights (6,7) on the bottom
flashes in red.