V003. 25.06.2002
B-7
Figure – 5
7- Open the cable panels from rear in order to facilitate the access.
8- In order to connect the main rack and the auxiliary racks, as well as to make inter-rack
ground connection: First, use the BPL200-FC and BPLSPS-FC connection cables that
come with the auxiliary rack. There are three such cables. Two BPL200-FC's (34-pin flat
cable) are used for connecting the BPL200 backplanes and BPLSPS-FC (5-wire cable) is
used for connecting BPL200-SPS backplanes. In order to connect the backplanes:
a) Primarily, attach one end of each BPL200-FC to the BPL200-MAIN backplane of the
main rack that has been placed to the bottom.
b) Extend the free ends of the BPL200-FC cables to the second rack through the cable
holes corresponding to the upper panel at the back of the first rack and the lower
panel at the back of the second rack. Attach the ends of those two cables to the
BPL200-AUX backplane connector. The cables should be parallel to each other.
Repeat the same procedure to connect the second rack to the third, later. See Figure
– 2.