DS200 Installation Guide
DS200 Installation Guide
DS200 Installation Guide
DS200 Installation Guide
V003. 25.06.2002
B-3
9- Hold the exchange so that the wall mount bar holes at the back of the exchange
correspond to the wall mount bar holders, then push the exchange towards the wall, so
that the holders would carry it. Make sure the holders of both wall mount bars have been
inserted into the holes, and then lower the exchange cautiously. The exchange is fixed 5
mm. below. If it is still not fixed, even though it has been lowered for about one
centimeter, that indicates the holders do not carry it. In that case, try to hang the
exchange once again. In order to make sure that the exchange has been fixed, gently
shake it to check whether the wall mount bars really carry it.
10- In case it is necessary to displace the exchange, just lift it upwards cautiously and pull it
out.
!
IT IS ESSENTIAL TO MOUNT AND DISMOUNT THE WALL MOUNT BARS
SIMULTANEOUSLY; OR THEY MAY GET DISTORTED.
11- If the second rack will be installed, then remove the top cover of the lower rack and the
bottom cover of the upper rack, in order to attach the cables that will connect the racks
to each other (Caution is needed for the grounding cables, as explained in the seventh
step.) The BPL200 main boards are connected to each other by the BPL200-FC and
BPLSPS-FC connection cables that come with the shipped hardware of the auxiliary rack.
There are three such cables. Two BPL200-FC's (34-pin flat cable) are used for connecting
the BPL200 backplanes and the single BPLSPS-FC (5-wire cable) is used for combining
BPL200-SPS backplanes.
1. BPL200-FC connections
2. BPLSPS-FC connection