DS200 Installation Guide
DS200 Installation Guide
DS200 Installation Guide
DS200 Installation Guide
V003. 25.06.2002
B-37
If you observe problems with LEDs of the CPU200, CC Enable, UTIL200 and SPS248 modules,
then shut down the system and replace the modules whose LEDs are off with new ones. Put
the system on line again, afterwards.
If the lower LED of any of the EX200 or EVM200L cards is off, then it is likely that there is a
problem with that card. In that case:
1) Cut the power to that card through the operator telephone by programming,
2) Replace the card with a new one,
3) Power the new card, again, through the operator telephone by programming.
The programming procedure for that purpose is as follows:
a) Dial 877777 through the operator telephone and wait for the dial tone,
b) Cut the power to the card by dialing 800950, then the slot number of the card and
finally 0. At that point, you are supposed to receive either the dial tone or the error
tone.
c) Remove the card from its slot by disconnecting it from the line connection card and
take it out of the system.
d) Place the new card into the slot by plugging the line connection card.
e) Power the card, again, through the operator telephone, by dialing 800950, then the
slot number of the card and finally 1.
NOTE: In order to power the card again, as explained above, a period of at least 30 seconds
must pass after the power is cut.
The table below illustrates card locations and slot numbers for a 6-rack system:
Sixt
h rack
94
80
81
82
83
84
85
86
87
88
89
90
91
92
93
Fif
th
r
ack
78
64
65
66
67
68
69
70
71
72
73
74
75
76
77
SE
CON
D
CA
B
IN
ET
Fo
ur
th
r
ack
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62